35
Fig. 5
Vertical flue terminal 3/5 in. (
Ø
80-125 mm) PP flue
gases/air for pitched roof
BWCAAG000120
BWHAAG000120
BWCAAG000150
BWHAAG000150
Max length (L)
45 ft (13.71 m)
65 ft (19.81 m)
Terminal length (L1)
4.42 ft (1.35 m)
4.42 ft (1.35 m)
fig. 5
increaser 2”-3”
V
ent adaptor Ø 80 mm
(factory supplied)
Fig. 6
Vertical flue terminal 3/5 in. (
Ø
80-125 mm) PP flue
gases/air for flat roof
BWCAAG000120
BWHAAG000120
BWCAAG000150
BWHAAG000150
Max length (L)
45 ft (13.71 m)
65 ft (19.81 m)
Terminal length (L1)
4.42 ft (1.35 m)
4.42 ft (1.35 m)
fig. 6
Vent adaptor Ø 80 mm
(factory supplied)
increaser 2”-3”
Fig. 7
Twin flue system 2 in. PP (
Ø 60 mm)
BWCAAG000120
BWHAAG000120
BWCAAG000150
BWHAAG000150
Max length (L) 30.5+30.5 ft (9.30+9.30 m)
28+28 ft (8.53+8.53 m)
Max length (L1) 25.5+25.5 ft (7.77+7.77 m)
23+23 ft (7.01+7.01 m)
90° bend
5 ft (1.52m)
5 ft (1.52m)
the expressed lengths are without the terminations
fig. 7
Fig. 8
Twin flue system 2 in. (
Ø 60 mm) with horizontal
terminal 2/4 in. (Ø
60 /100 mm) PP flue gases/air
BWCAAG000120
BWHAAG000120
BWCAAG000150
BWHAAG000150
Max length (L)
25.5 + 25.5 ft
(7.77 + 7.77m)
23 + 23 ft
(7.01+7.01 m)
Terminal length (L1)
2.33 ft (0.71 m)
2.33 ft (0.71 m)
fig. 8
cut exceeding external pipe