5
Fig. 3 — 50VQP168-300 Unit Dimensions
CONNECTIONS
50VQP168-240
50VQP300
Water Inlet (See Note 7)
2 in. FPT
2
1
/
2
in. FPT
Water Outlet (See Note 7)
2 in. FPT
2
1
/
2
in. FPT
Condensate Drain (See Note 8)
1 in. FPT
1 in. FPT
High Voltage Access (See Note 9)
1
3
/
8
in.
1
3
/
8
in.
Low Voltage Access (See Note 9)
7
/
8
in.
7
/
8
in.
1
2
3
4
5
a50-8437
UNIT
50VQP
OVERALL
CABINET (cm)
DISCHARGE
CONNECTIONS (cm)
Duct Flange
WATER
CONNECTIONS (cm)
ELECTRICAL
KNOCKOUTS (cm)
RETURN AIR
CONNECTIONS (cm)
(Using Return Air Opening)
A
Depth
B
Width
C
Height
D
Supply
Width
E
Supply
Depth
F
G
K
1-Water
Inlet
L
2-Water
Outlet
M
3-
Condensate
N
O1
O2
P
Q
R
S
Return
Depth
T
Return
Height
U
V
168-240
86.4
270.9
200.7
44.5
44.6
45.1
79.4
78.7
7.6
68.6
65.1
78.1
96.4
87.8
2.5
7.6
121.9
82.2
113.3
6.9
300
86.4
270.9
200.7
54.4
44.6
45.1
59.4
78.7
7.6
68.6
65.1
78.1
96.4
87.8
2.5
7.6
121.9
82.2
113.3
6.9
LEGEND
NOTES:
1. All dimensions in centimeters.
2. Units require 91 cm clearance for water connections, CAP, CSP, MSP, and BSP service access.
3. Overall cabinet height dimension does not include duct flange when in top discharge configuration.
4. Overall cabinet width dimension does not include filter rack and duct flange when on front or back dis-
charge configuration.
5. Side service access must be 91 cm on either side that connections are made. If no connections are made
on a side, then service access can be 15 mm minimum.
6. While access to all removable panels is not required, installer should take care to comply with all building
codes and allow adequate clearance for future field service.
7. Water inlet and water outlet connections are available on either side (left or right) of the unit. Two MPT
plugs are shipped loose in a plastic bag tied to the water leg in front of the unit. Installer must plug water
inlet/outlet side not being connected to.
8. Condensate drain is available on either side (left or right) of unit. Drain hose and drain connection will be
tied inside the unit. Installer must untie the drain hose and connect to the condensate drain hole of
installer’s choice.
9. Electrical access is available on either side (left or right) of unit and is also available (left or right) in the
front of the unit.
10. Overall depth — add 7.9 cm for 2.5 or 5 cm filter. Add 13 cm for 10 cm filter.
BSP
— Blower Service Panel
CAP
— Control Access Panel
CSP
— Compressor Service Panel
MSP
— Motor Service Panel
NRP
— Non-Removable Panel
REAR RETURN TOP DI
S
CHARGE
FRONT RETURN TOP DI
S
CHARGE
FRONT RETURN REAR DI
S
CHARGE
Control Box
C
S
P
C
S
P
NRP
CAP
M
S
P
NRP
NRP
RETURN AIR
RETURN AIR
AIR OUT
AIR OUT
B
S
P
B
S
P
01
P
02
C
NRP
19.
3
V
B
A
NOTE 5
F
D
G
D
E
S
N
U
T
K
M
L
3
2
1
R
Q
E
S
3
Control Box
C
S
P+M
S
P
NRP
NRP
RETURN AIR
RETURN AIR
AIR OUT
AIR OUT
F
L
3
1
2
3
C
S
P+CAP
19.
3
B
S
P
4
5
4
4
5
4
K
M
NRP
Control Box
C
S
P+M
S
P
NRP
NRP
RETURN AIR
RETURN AIR
AIR OUT
AIR OUT
F
3
1
2
3
C
S
P+CAP
B
S
P
4
5
4
4
5
4
NRP
Control Box
C
S
P
NRP
CAP
M
S
P
NRP
AIR OUT
AIR OUT
NRP
E
NRP
4.
3
F
D
G
D
2
1
3
4
5
4
4
5
4
C
S
P
REAR RETURN FRONT DI
S
CHARGE
RETURN
AIR
RETURN
AIR
B
S
P
S
ide
S
ervice Acce
ss
(
S
ee Note)
S
ervice Acce
ss
3’
(91 cm)
Front
a
nd B
a
ck
(All Config
u
r
a
tion
s
)
3
ALL CONFIGURATION
S
REQUIRE
S
ERVICE ACCE
SS
AREA
S
HOWN BELOW