41
11 - OPTIONs aND aCCEssORIEs
Options
No.
Description
advantages
Use
Corrosion protection, traditional
coils
2B
Factory application of Blygold Polual treatment on the
copper/aluminium coils
Improved corrosion resistance, recommended
for industrial, rural and marine environments
30XA 252-1702
Corrosion protection, traditional
coils
3A
Fins made of pre-treated aluminium (polyurethane and
epoxy)
Improved corrosion resistance, recommended
for moderate marine and urban environments
30XA 252-1702
Low temperature glycol solution
5
Low temperature chilled water production down to -6°C
with ethylene glycol and -3°C with propylene glycol
Covers specific applications such as ice storage
and industrial processes
30XA 252-1702
Very low temperature glycol
solution
6
Low temperature chilled water production down to -12°C
with ethylene glycol (limited to -10°C for certain sizes)
and -8°C with propylene glycol (limited to -6°C for certain
sizes)
Covers specific applications such as ice storage
and industrial processes
30XA 252-1702
IP 54 control box
20A
Increased leak tightness of control boxes
Increased control box protection
30XA 252-1702
Tropical applications
22
Unit control box suitable for tropical applications
Reduced relative humidity in the control box for
operation in tropical environments (hot and humid)
30XA 252-1702
Grilles
23
Metallic grilles on the unit front, rear and sides
Enhanced aesthetics, protection against
intrusion to the unit interior
30XA 252-1702
Winter operation
28
Fan speed control via frequency converter
Stable unit operation when the air temperature is
between -10°C and -20°C
30XA 252-1702
Evaporator frost protection
41A
Resistance heater on the evaporator
Evaporator frost protection down to -20°C
outside temperature
30XA 252-1702
Evaporator and hydronic module
frost protection
41B
Resistance heater on the evaporator and the hydronic
module
Evaporator and hydronic module frost protection
down to -20°C outside temperature
30XA 252-1502
Heat reclaim
50
Complete recovery of the heat rejected by the
condenser
Free hot-water production as well as cold-water
production
30XA 252-1002
Single power connection point
81
Power connection of the machine via one main supply
connection
Quick and easy installation
30XA 252-1502
Suction valve
92
Shut-off valves on the compressor suction piping, the
economiser line and the compressor discharge piping
Simplified maintenance
30XA 252-1702
Three-pass evaporator
100A Evaporator with three passes water-side
Increased water inlet and outlet pressure losses
on opposite sides
30XA 252-602
One-pass evaporator
100C Evaporator with one pass water-side
Reduced water inlet and outlet pressure losses
on opposite sides
30XA 252-1002
21 bar evaporator
104
Reinforced evaporator for extension of the maximum
water-side service pressure range to 21 bar
Covers applications with a high water column
(high buildings)
30XA 252-1702
Reversed water connections
107
Evaporator with reversed water inlet/outlet
Simplification of the water piping
30XA 252-1702
High-pressure single-pump
hydronic module
116B See hydronic module chapter
Easy and fast installation
30XA 252-502
High-pressure dual-pump
hydronic module
116C See hydronic module chapter
Easy and fast installation, operating safety
30XA 252-502
Low-pressure single-pump
hydronic module
116F See hydronic module chapter
Easy and fast installation
30XA 252-502
Low-pressure dual-pump
hydronic module
116G See hydronic module chapter
Easy and fast installation, operating safety
30XA 252-502
Direct-expansion free-cooling
system
118A Chilled water production without the use of the
compressors, using direct-expansion heat exchange on
the condensers
Very economical chilled water production at low
outdoor temperatures
30XA 252-1002
High energy efficiency
119
Improved condenser performance
Energy cost reduction, full load operation at
higher air temperatures
30XA 252-1702
JBus gateway
148B Two-directional communications board, complies with
JBus protocol
Easy connection by communication bus to a
building management system
30XA 252-1702
BacNet gateway
148C Two-directional communications board, complies with
BacNet protocol
Easy connection by communication bus to a
building management system
30XA 252-1702
LON gateway
148D Two-directional communications board, complies with
LON protocol
Easy connection by communication bus to a
building management system
30XA 252-1702
Energy Management Module
EMM
156
See chapter “Energy Management Module”
Easy connection by wired connection to a
building management system
30XA 252-1702
Unit without enclosure
253
Compressors not equipped with acoustic enclosure
More economical
30XA 252-1702
Traditional coils (Cu/Al)
254
Coils made of copper tubes with aluminium fins
Possibility to add specialised condenser
treatment
30XA 252-1702
Traditional coils (Cu/Al) without
slots
255
Coils made of copper tubes with aluminium fins without
slots
Recommended for the Middle East, sand storms.
Possibility to add specialised condenser treatment.
30XA 252-1702
Suction piping insulation
256
Thermal insulation of the suction piping with flexible,
anti-UV insulant
Prevents condensation on the suction piping
30XA 252-1702
Low sound level
257
Acoustical insulation of certain unit refrigerant circuit
components (suction, evaporator and economiser piping)
Unit sound power level reduction of -3 dB(A)
30XA 252-1702
accessories
Description
advantages
Use
CCN JBus gateway
See option 148B
See option 148B
See option 148B
CCN BacNet gateway
See option 148C
See option 148C
See option 148C
CCN LON Talk gateway
See option 148D
See option 148D
See option 148D
Connection sleeve
Piping to be welded with Victaulic connection
Ease-of-installation
30XA 252-1702
Energy Management Module
EMM
See controls manual
Easy connection by wired connection to a
building management system
30XA 252-1702
Lead-lag kit
Supplementary water outlet temperature sensor kit, field-
installed, allows master/slave operation of two chillers
connected in parallel.
Optimised operation of two chillers connected in
parallel with operating time balancing.
30XA 252-1502
Anti-vibration mountings
Elastomeric anti-vibration mountings for each unit weight
distribution point
Absorption of vibrations, linked to the unit
operation (essentially compressor)
30XA 252-1702
Содержание Aqua Force 30XA
Страница 47: ......