42HQE009/012/018/022-38YE009/012/018/022  

GB - 2

IMPORTANT:
• For correct installation, read this manual before starting

installation.

• Only trained and qualified service personnel should install, repair

or service air conditioning equipment.
Users should not install the air conditioner by themselves.

• All pictures are only sketches. If there is any difference between

pictures in this manual and the actual shape of the air conditioner
you purchased, the actual shape shall prevail.

Installation precaution

Installation in the following places  may cause  trouble.
If it  is  unavoidable,  please, consult  with the local dealer.

• A place full of machine oil.

• A saline place such as coast.

• A place full of sulfide gas such as hot-spring resort.

• Places where there are high frequency machines such as wireless

equipment, welding  machine, and medical facility.

• A place of special environmental conditions.

• The appliance shall not be installed in the laundry.

Indoor Unit

• A place where is no obstacle near  the inlet and outlet area.

• A place which  can bear  the weight  of the indoor unit.

• A place which  allows  the  air  filter  to  be removed.

• A place where  the  reception range  is not exposed to direct

sunlight.

• A place  where  the  connective  pipe  and drain hose is easy to

led out.

• A place 1m or more to TV, radio instrument, in the center of the

room is perfect.

• The indoor unit should  be installed 2.3 meters or more above the

floor.

Outdoor Unit

• A place, which is convenient to installation and not exposed  to a

strong wind.

A place that is dry and ventilated.

• A place can bear the weight of the outdoor unit and where the

outdoor unit can be held in the horizontal position.

• A place  which does not  allow an increase in noise level and

vibration.

• A place where the operation noise and discharge air do not

disturb your neighbor.

• A place  free of  a  leakage of combustible gases.
• An allowable  head  level at the connective piping is  less  than

5m  and  length of the connective piping is up less than 10m.

• No any obstacle which block radiat air.
• Unavailable to children.
• A place which provides the space around the outdoor unit as

required in the diagram of page 3.

General information

Unit installation

• Restrictions to connection may be imposed by the supply authority

on the use of equipment  if the actual system impedance at the
interface point on the user’s premises exceeds 0.115 ohms for
38YE009, 012, 018 and 0.25 ohms for  38YE022.

• The unit complies with low-voltage (EEC/73/23) and

electromagnetic compatibility (EEC/89/336) directives.

• Carefully recover refrigerant within this unit before final disposal or

when servicing. Never vent refrigerant to atmosphere.

• All of the manufacturing and packageing material used for your new

appliance are compatible with the environment and can be recycled.

• Disconnect the mains power supply switch and wait over 2

minutes without toughing any internal parts of the unit before
servicing the system or handing any internal parts of the unit.

• All field electrical connections are the responsibility of the installer.

• If not using plug, ensure that mains supply connection is made

through a switch that disconnects all poles, with contact gap of a
least 3mm.

• There are some kinds of cord clamp in the accessory parts. If cord

clamp is not used as specified, the power cable and
interconnection wire will be damaged.

• The equipment contains R-407C refrigerant, a substance that is

not depleting the ozone layer but must be disposed of in a proper
manner. When disposing of the unit after its operational life,
remove it carefully.

• Check that the impedance of the mains power supply is in

conformance with the unit power input indicated in the electric
(EN 61000-3-11).

• Control batteries contain polluting elements. When exhausted

they must be disposed of according to local requirements.

• After the installation thoroughly test system operation and explain

all system functions to the owner.

• Leave this manual with the owner for consultation during future

periodic maintenance.

• Use this unit only for factory approved applications:the unit cannot

be used in laundry or steam pressing premises.

• Follow all current national safety code requirements. In particular

ensure that a property sized and connected ground  wire is in place.

• Check that voltage and frequency of the mains power supply are

those required for the unit to be installed;the available power must
be adequate to operate any other possible appliances connected
to the same line.

• The manufacturer declines any liability for damage resulting  from

modifications or errors in the electrical or refrigerant connections.

• Failure to observe the installation instructions or use of the  unit

under conditions other than those indicated in operating limits ,
will immediately void the unit warranty.

• Failure to observe electric safety codes may cause a fire hazard in

case of short circuits.

• Inspect equipment for damage due to improper transportation or

handing: file an immediate claim with the shipping company.
Do not install or use damaged units.

Содержание ALLEGRO 38YE009

Страница 1: ...42HQE009 012 018 022 38YE009 012 018 022 INSTALLATION MANUAL...

Страница 2: ...ting installation plate 4 Connective Pipe and Drainage Installation 4 Dimensions and Minimum clearance 5 Wiring connection 6 Connecting Cables 6 Terminal block of indoor unit 6 Outdoor unit installati...

Страница 3: ...The unit complies with low voltage EEC 73 23 and electromagnetic compatibility EEC 89 336 directives Carefully recover refrigerant within this unit before final disposal or when servicing Never vent...

Страница 4: ...its location in a reception range Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment Do not install the remote controller in a place exposed to direct sunlight or...

Страница 5: ...d and rear left hand piping install the piping as shown Bend the connective pipe to be laid at 43 mm height or less from the wall 3 Fix the end of the connective pipe Refer to Tightening Connection in...

Страница 6: ...asily be made by lifting the indoor unit B A C Dimensions and Minimum clearances mm Model 42HQE009 42HQE012 42HQE018 42HQE022 A mm 750 815 906 1080 B mm 250 280 286 330 C mm 188 195 235 222 Upper hook...

Страница 7: ...nditioner takes a grounding leg so clients should use a grounding socket so that the air conditioner can be grounded efficiently If the power cord is damaged replacement should be conducted by qualifi...

Страница 8: ...e If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram Outdoor unit installation A B C D E A F Minimum clearances mm Mo...

Страница 9: ...e outdoor unit 2 Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units 3 To prevent the ingress of water...

Страница 10: ...ld valve and stop the operation of the vacuum pump Make evacuation for 15 minutes and more and check that the compound meter indicates 76cmHg 1 0x105 Pa 6 Disconnect the charge hose from the charge co...

Страница 11: ...42HQE 38YE IOM Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice December 2004...

Отзывы: