Alarm signals - Supply Refrigeration unit using AddVolt system 

 
If ON is yellow and AddVolt system is not starting:  

1.

 

Press and rotate the Service Disconnect;  

2.

 

Press the green button until ON is white, restarting AddVolt system. 

3.

 

If the alarm persists please contact your AddVolt service partner 
 

If the ON and OFF buttons are grey: 

1.

 

Press and rotate the Service Disconnect;  

2.

 

Press the green button until ON is white, restarting AddVolt system. 

 

5.2

 

Alarm signals 

 SOC too low  

 

The autonomy of the AddVolt system is too low, below 25%. 
Please charge the AddVolt un it connecting it to the power grid. 

 

 

5.3

 

Alarm signals - System blackout  

 

When the system is critically discharged, it shuts down for safety and all the lights are off.  

 

To initiate safe charging, the user must proceed as follows:

 

1.

 

Connect the vehicle to the power grid;  

2.

 

Press the green button until the   is lit in white and AddVolt system starts charging.  
 

5.4

 

Alarm signals - Charging and supplying the Refrigeration unit 

 

When the motor indicator is red, please proceed as described below. 

If the vehicle is connected to the power grid with the Refrigeration unit already in 
operation:  

1.

 

Turn OFF the Refrigeration unit, keeping the power grid cable connected;  

2.

 

Turn ON the Refrigeration unit again. 

 

 

Содержание AddVolt

Страница 1: ...62 61974 01 User Manual...

Страница 2: ...Volt system connected to the power grid 10 4 5 Charging and supplying the Refrigeration unit 11 4 6 Charging the AddVolt unit through the generator 12 4 7 Charging and supplying the Refrigeration unit...

Страница 3: ...50Hz grid on board of the vehicle making possible supply the electrical standby motor anytime Main benefits of the AddVolt systems Enables day and night access to city centers Compatible with all veh...

Страница 4: ...installed in drawbars or trailers 1 AddVolt Plug in Electric system attached to the vehicle 2 Display 3 My AddVolt digital platform for monitoring by the fleet manager Every product is accompanied by...

Страница 5: ...R ADDM2517 R ADDM3014 R ADDM3817 R ADDL3021 R may be used in load constantly at temperatures below zero to avoid the battery internal temperature to drop below 0 C for Charging and 11 C for dischargin...

Страница 6: ...h danger to people with heart pacemakers metal implants and hearing aids People with a heart pacemaker metal implants or hearing aids must consult a doctor before they enter areas nearby the AddVolt s...

Страница 7: ...ut of the outlets directly by the cables Always pull by the connectors Before removing the vehicle from the dock disconnect vehicle from the power grid Cables that are damaged may cause Electrocutions...

Страница 8: ...e Refrigeration unit in electric mode make sure that the green button of the AddVolt system is pressed as shown in the image In this case the only button that must be actuated is the green button The...

Страница 9: ...energy The OFF light of the display will appear in white 4 3 Supply Refrigeration unit using AddVolt system Whenever the user needs to operate the Refrigeration unit in electric mode and the AddVolt...

Страница 10: ...charging automatically and the ON light will be either blinking or lit in white 5 The autonomy indicators will blink during charge representing the battery level Notes 1 When the vehicle is parked It...

Страница 11: ...Refrigeration unit will start automatically 6 The display will activate the electric motor indicator meaning that the Refrigeration unit is operating in electric mode 7 Wait 30 seconds the system will...

Страница 12: ...evel 4 7 Charging and supplying the Refrigeration unit through the generator Whenever the generator is producing energy while the refrigeration unit is operating at the same time 1 The system will sta...

Страница 13: ...turn service disconnect OFF and ON Follow instructions in Alarm Signal section Fuse in FUBO Fuse Box broken Press the service disconnect and disconnect from power grid Measure continuity of all fuses...

Страница 14: ...low below 25 Please charge the AddVolt un it connecting it to the power grid 5 3 Alarm signals System blackout When the system is critically discharged it shuts down for safety and all the lights are...

Страница 15: ...aintenance must be performed only by trained and approved personnel by AddVolt This unit operates with high voltage levels Use insulated tools whenever necessary Make sure the device is shutdown 15 mi...

Страница 16: ...in the power or signal cables Monthly Check electrical connections inside the fuse box Every 6 month Mechanical coupling Check if device s screws to chassis have moved At each vehicle overhaul minimum...

Страница 17: ...st Carrier Transicold service centre Consult the directory to locate the service centre nearest you This directory may be obtained from your Carrier Transicold dealer If you are unable to reach a serv...

Страница 18: ...Your name the name of your company and your location A telephone number where you can be called back Refrigeration unit model and serial number Box temperature Set point and product Brief description...

Отзывы: