Maintenance and Service  

Choosing to maintain the unit in a preventive way is one of  AddVolt and its certified service 
partners recommendations, giving the unit greater longevity in its maximum performance.  

Choosing  this  type  of  unit  continuous  monitoring  will  also  confer  greater  control  over  the 
operational costs of the equipment. 

The safety and comfort of our customers are one of AddVolt main priorities on a daily basis. For 
this reason, a maintenance program has been developed and presented below. 

 WARNING! 

Device maintenance must be performed only by trained and approved personnel by AddVolt.  

This unit operates with high voltage levels. Use insulated tools whenever necessary. 

Make  sure  the  device  is  shutdown  15  minutes  before  any  intervention,  to  allow  for  all 
residual  voltages  to  be  internally  discharged  to  a  safe  level.  Make  sure  no  terminal  has 
voltage before any intervention. 

Depending on configuration, the unit may start automatically on power-up. 

 

 DANGER! 

Before performing any service in any AddVolt unit press the service disconnect (red button 
on fuse box near battery system). 

 

 

 

 

 

 

To restart the system after the service intervention: 

1.

 

Rotate the Service Disconnect button;  

2.

 

Press the green button and both the system and the display will start. 

 

 

Содержание AddVolt

Страница 1: ...62 61974 01 User Manual...

Страница 2: ...Volt system connected to the power grid 10 4 5 Charging and supplying the Refrigeration unit 11 4 6 Charging the AddVolt unit through the generator 12 4 7 Charging and supplying the Refrigeration unit...

Страница 3: ...50Hz grid on board of the vehicle making possible supply the electrical standby motor anytime Main benefits of the AddVolt systems Enables day and night access to city centers Compatible with all veh...

Страница 4: ...installed in drawbars or trailers 1 AddVolt Plug in Electric system attached to the vehicle 2 Display 3 My AddVolt digital platform for monitoring by the fleet manager Every product is accompanied by...

Страница 5: ...R ADDM2517 R ADDM3014 R ADDM3817 R ADDL3021 R may be used in load constantly at temperatures below zero to avoid the battery internal temperature to drop below 0 C for Charging and 11 C for dischargin...

Страница 6: ...h danger to people with heart pacemakers metal implants and hearing aids People with a heart pacemaker metal implants or hearing aids must consult a doctor before they enter areas nearby the AddVolt s...

Страница 7: ...ut of the outlets directly by the cables Always pull by the connectors Before removing the vehicle from the dock disconnect vehicle from the power grid Cables that are damaged may cause Electrocutions...

Страница 8: ...e Refrigeration unit in electric mode make sure that the green button of the AddVolt system is pressed as shown in the image In this case the only button that must be actuated is the green button The...

Страница 9: ...energy The OFF light of the display will appear in white 4 3 Supply Refrigeration unit using AddVolt system Whenever the user needs to operate the Refrigeration unit in electric mode and the AddVolt...

Страница 10: ...charging automatically and the ON light will be either blinking or lit in white 5 The autonomy indicators will blink during charge representing the battery level Notes 1 When the vehicle is parked It...

Страница 11: ...Refrigeration unit will start automatically 6 The display will activate the electric motor indicator meaning that the Refrigeration unit is operating in electric mode 7 Wait 30 seconds the system will...

Страница 12: ...evel 4 7 Charging and supplying the Refrigeration unit through the generator Whenever the generator is producing energy while the refrigeration unit is operating at the same time 1 The system will sta...

Страница 13: ...turn service disconnect OFF and ON Follow instructions in Alarm Signal section Fuse in FUBO Fuse Box broken Press the service disconnect and disconnect from power grid Measure continuity of all fuses...

Страница 14: ...low below 25 Please charge the AddVolt un it connecting it to the power grid 5 3 Alarm signals System blackout When the system is critically discharged it shuts down for safety and all the lights are...

Страница 15: ...aintenance must be performed only by trained and approved personnel by AddVolt This unit operates with high voltage levels Use insulated tools whenever necessary Make sure the device is shutdown 15 mi...

Страница 16: ...in the power or signal cables Monthly Check electrical connections inside the fuse box Every 6 month Mechanical coupling Check if device s screws to chassis have moved At each vehicle overhaul minimum...

Страница 17: ...st Carrier Transicold service centre Consult the directory to locate the service centre nearest you This directory may be obtained from your Carrier Transicold dealer If you are unable to reach a serv...

Страница 18: ...Your name the name of your company and your location A telephone number where you can be called back Refrigeration unit model and serial number Box temperature Set point and product Brief description...

Отзывы: