background image

 

17 

62-61974-01 

7

 

24/7 Assistance  

At Carrier Transicold we're working hard to give you complete service when and where you need 
it.  That  implies  a  worldwide  network  of  dealers  and  available  an  emergency  service.  These 
service centres are manned by factory-trained service personnel and backed by extensive parts 
inventories that will assure you of prompt repair. 

Should  you  encounter  a  unit  problem  with  your  AddVolt  unit  during  transit,  follow  your 
company's  emergency  procedure  or  contact  the  nearest  Carrier  Transicold  service  centre. 
Consult the directory to locate the service centre nearest you. This directory may be obtained 
from your Carrier Transicold dealer. 

If you are unable to reach a service centre, call Carrier 

Transicold’s 24Hour Assistance: ONE CALL.

 

In Europe, please use the following free phone numbers from: 
 

AT 

AUSTRIA 

0800 291039 

BE 

BELGIUM 

0800 99310 

CH 

SWITZERLAND 

0800 838839 

DE 

GERMANY 

0800 1808180 

DK 

DENMARK 

808 81832 

ES 

SPAIN 

900 993213 

FR 

FRANCE 

0800 913148 

FI 

FINLAND 

0800113221 

GB 

GREAT BRITAIN 

0800 9179067 

GR 

GREECE 

00800 3222523 

HU 

HUNGARY 

06800 13526 

IT 

ITALY 

800 791033 

IE 

IRELAND 

1800 553286 

LU 

LUXEMBURG 

800 23581 

RU 

RUSSIA 

810 800 200 31032 

NO 

NORWAY 

800 11435 

Содержание AddVolt

Страница 1: ...62 61974 01 User Manual...

Страница 2: ...Volt system connected to the power grid 10 4 5 Charging and supplying the Refrigeration unit 11 4 6 Charging the AddVolt unit through the generator 12 4 7 Charging and supplying the Refrigeration unit...

Страница 3: ...50Hz grid on board of the vehicle making possible supply the electrical standby motor anytime Main benefits of the AddVolt systems Enables day and night access to city centers Compatible with all veh...

Страница 4: ...installed in drawbars or trailers 1 AddVolt Plug in Electric system attached to the vehicle 2 Display 3 My AddVolt digital platform for monitoring by the fleet manager Every product is accompanied by...

Страница 5: ...R ADDM2517 R ADDM3014 R ADDM3817 R ADDL3021 R may be used in load constantly at temperatures below zero to avoid the battery internal temperature to drop below 0 C for Charging and 11 C for dischargin...

Страница 6: ...h danger to people with heart pacemakers metal implants and hearing aids People with a heart pacemaker metal implants or hearing aids must consult a doctor before they enter areas nearby the AddVolt s...

Страница 7: ...ut of the outlets directly by the cables Always pull by the connectors Before removing the vehicle from the dock disconnect vehicle from the power grid Cables that are damaged may cause Electrocutions...

Страница 8: ...e Refrigeration unit in electric mode make sure that the green button of the AddVolt system is pressed as shown in the image In this case the only button that must be actuated is the green button The...

Страница 9: ...energy The OFF light of the display will appear in white 4 3 Supply Refrigeration unit using AddVolt system Whenever the user needs to operate the Refrigeration unit in electric mode and the AddVolt...

Страница 10: ...charging automatically and the ON light will be either blinking or lit in white 5 The autonomy indicators will blink during charge representing the battery level Notes 1 When the vehicle is parked It...

Страница 11: ...Refrigeration unit will start automatically 6 The display will activate the electric motor indicator meaning that the Refrigeration unit is operating in electric mode 7 Wait 30 seconds the system will...

Страница 12: ...evel 4 7 Charging and supplying the Refrigeration unit through the generator Whenever the generator is producing energy while the refrigeration unit is operating at the same time 1 The system will sta...

Страница 13: ...turn service disconnect OFF and ON Follow instructions in Alarm Signal section Fuse in FUBO Fuse Box broken Press the service disconnect and disconnect from power grid Measure continuity of all fuses...

Страница 14: ...low below 25 Please charge the AddVolt un it connecting it to the power grid 5 3 Alarm signals System blackout When the system is critically discharged it shuts down for safety and all the lights are...

Страница 15: ...aintenance must be performed only by trained and approved personnel by AddVolt This unit operates with high voltage levels Use insulated tools whenever necessary Make sure the device is shutdown 15 mi...

Страница 16: ...in the power or signal cables Monthly Check electrical connections inside the fuse box Every 6 month Mechanical coupling Check if device s screws to chassis have moved At each vehicle overhaul minimum...

Страница 17: ...st Carrier Transicold service centre Consult the directory to locate the service centre nearest you This directory may be obtained from your Carrier Transicold dealer If you are unable to reach a serv...

Страница 18: ...Your name the name of your company and your location A telephone number where you can be called back Refrigeration unit model and serial number Box temperature Set point and product Brief description...

Отзывы: