6.3.1.3. Offsets
This option allows calibration (or deliberate miscalibration) of the
temperature and humidity sensors. These offsets are added to the actual
temperature/humidity values. See also Zone Offsets Section. When the
correct offsets are made, touch
SAVE
. If the system is non-zoned, the
indoor temperature offset is found on this screen. If the system is zoned,
the indoor temperature offset is found in the Zoning, Offsets screen.
•
Outdoor temperature
: Adjustable from -5 to 5°F (-3 to 3°C).
Default = 0°F
•
Indoor temperature
: Adjustable from -5 to 5°F (-3 to 3°C).
Default = 0°F
•
Humidity:
Adjustable from -10 – 10%. Default = 0%
NOTE:
For single-zone systems, the indoor temperature offset is on this
screen. For zoning systems, there is a separate zone indoor temperature
offset screen in the zoning menu.