31
L2
L1
1
PB
2
X1
C
O
G
R
Y
FAN SPEED SWITCH
(LOCATED IN COMPRESSOR COMPARTMENT)
1
2
3
SEE
NOTE 4
CR
Ground
CB
BRN
Use copper
Connection
Refer to Data Plate
Cord
Optional
conductors only.
Power Supply
BLK
NOTE 3
(115V)
WHT
RED
BRN
(265V)
(208V)
230V
ORG
1
BRN
CR
0
YEL
Neutral on 265V Systems
Ground
L2 (ribbed)
L1 (plain)
Trans
SEE
CAP
F
C
H
YEL
BRN
RED
BLK
2
6
RVS
Not Used
ORG
LOC
BRN
VIO
BRN
VIO
GRY
GRY
RED
BLU
RED
FP2
FP1
HP
NOTE 4
SEE
Compressor
B (HIGH)
A (LOW)
BM
1
2
BLU
BLK
RED
4
8
R
S
C
DM
BLK
RED
FSS
YEL
BRN
NLL
RED
YEL
WV
RED
Cap
PB
Ground
CR
Transformer
Deluxe
D
WHT
RED
Common
Alarm
Class 1 Wiring
required inside
control box
Compressor
Cooling
24 VAC
Fan
Class 1 or 2
Wiring acceptable
outside control box
Typical Heat
Pump T-stat
GRY
GRY
BLK
BLU
1
3
2
GRY
YEL
SEE NOTE 5
ORG
BRN
BRN
TIME CLOCK
CLOSED=UNOCCUPIED
OVERRIDE
OVERRIDE
OV
OV
OVERRIDE
WITH DIGITAL T-STAT
See Note 2
box for optional
Refer to Disconnect
power supply connection
YEL
YEL
SEE
NOTE 7
SEE
NOTE 7
Boilerless: Enable/Disable
T'stat: Heat Cool/Heat Pump
JW1
JW2
FP2
JW3
FP1
P3
NC1
COM
COM
NC2
NO2
NO1
R
R
ACC2
RELAY
RELAY
ACC1
DIP SWITCH
PACKAGE
Boilerless: 40
°
F/50
°
F
Dehumid/Normal
Unit Stage: 2/1
RV on B/RV on O
UPM: Disable/Enable
Not Used
2
8
4
6
7
5
3
S1
1
OFF ON
LP
RELAY
ALARM
C
7
ESD
OVR
AL2
NSB
A
H
C
R
AL1
P2
8
Y1
O/W2
G
R
W1
Y2
P1
1
4
6
5
3
2
R
C
AL2 DRY
NOTE 6
SEE
PINS
TEST
COM2
C
R
COM1
S
S
C
24V
DIP SWITCH
PACKAGE
H: hi fan/dehumid
ACC2
Not Used
Functions
Functions
ACC1
2
S2
6
7
8
4
5
3
N.O.
OFF
Low
Low
1
ON
COMPR
RELAY
CC
CCG
P6
EH2
DC
EH1
COM
FAN ENABLE
Control Logic
RELAY
FAULT
STATUS
R
RV
G
TEST
Y
Microprocessor
D
NO
COM
NO
1
FP2
CO
P7
12
RV
9
10
8
4
FP1
6
7
5
LOC
HP
3
2
NC
SPEED
RELAY
FAN
RELAY
JW4
NOTES:
1. Compressor and Blower Motor thermally protected
internally.
2. All wiring to the unit must comply with NEC and local
codes.
3. Transformer is wired to 115V (WHT) lead for 115/1/60
units, 265V (BRN) Lead for 265/1/60 units or 208V
(RED) Lead for 208/1/60. For 230/1/60 switch RED
and ORG Leads at L1 and insulate RED lead. Trans-
former is energy limiting or may have circuit breaker.
4. FP1 Thermistor provides freeze protection for
WATER. When using ANTI-FREEZE solutions, cut
JW3 jumper.
5. Typical heat pump thermostat wiring shown. Refer to
thermostat Installation Instructions for wiring to the
unit.
6. 24 V Alarm Signal shown. For Dry Alarm Contact, cut
AL2DRY(JW4) Jumper and Dry Contact will be avail-
able between AL1 and AL2.
7. Transformer secondary ground via Deluxe D board
standoffs and screws to Control Box. (Ground avail-
able from top two standoffs as shown.)
AL
—
Alarm Relay Contacts
BM
—
Blower Motor
Cap
—
Capacitor
CB
—
Circuit Breaker
CO
—
Condensate Overflow
CR
—
Compressor Relay
DM
—
Damper Motor
FP1
—
Sensor, Water Coil Freeze Protection
FP2
—
Sensor, Air Coil Freeze Protection
FSS
—
Fan Speed Switch
HP
—
High-Pressure Switch
LOC
—
Loss of Charge Pressure Switch
NLL
—
Night Low Limit Thermostat
P1
—
Field Wiring Terminal Block
PB
—
Power Terminal Block
RVS
—
Reversing Valve Solenoid
Trans —
Transformer
UPM
—
Unit Performance Monitor
WV
—
Water Valve
BLOWER MOTOR WIRING
UNIT SIZE
POLE A
POLE B
007
5
3
009
5
3
012
5
4
015
4
3
019
4
3
REMOTE-MOUNTED THERMOSTAT WITH DELUXE D CONTROLLER
LEGEND
----------
Field Line Voltage Wiring
Field Low-Voltage Wiring
Printed Circuit Trace
Optional Low Voltage
Wiring
Relay Contactor Coil
Solenoid Coil
Thermistor
Ground