CORNER WEIGHTS (SMALL CABINET)
CORNER WEIGHTS (LARGE CABINET)
Unit
018
024
030
036
Unit
042
048
060
lb
kg
lb
kg
lb
kg
lb
kg
Total Weight
lb
kg
lb
kg
lb
kg
Total Weight
282
127.9
296
134.2
313
142.0
338
153.3
Total Weight
401
181.9
418
189.6
446
202.3
Corner
Weight 1
73
33.1
59
26.8
55
25.1
72
32.5
Corner
Weight 1
68
30.6
62
28.1
54
24.5
Corner
Weight 2
60
27.4
84
38.0
95
42.9
89
40.3
Corner
Weight 2
119
53.8
135
61.2
158
71.7
Corner
Weight 3
95
43.0
81
36.8
78
35.2
95
43.0
Corner
Weight 3
60
27.2
64
29.2
81
36.6
Corner
Weight 4
54
24.4
72
32.6
85
38.7
83
37.5
Corner
Weight 4
155
70.3
157
71.1
154
69.7
Rigging
Weight
301
136.5
315
142.9
332
150.6
357
161.9
Rigging
Weight
423
191.8
440
199.5
468
212.2
Shipping
Weight
336
152.4
350
158.7
367
166.4
392
177.8
Shipping
Weight
463
210.0
480
217.7
508
230.4
Fig. 6 -- 48ES Unit Corner Weights (in Pounds) and Suggested Rigging
Step 6—Connect Condensate Drain
NOTE
: When installing condensate drain connection be sure to
comply with local codes and restrictions.
Model 48ES disposes of condensate water through a 3/4 in. NPT
fitting which exits through the base on the evaporator coil access
side. See Fig. 3 & 4 for location.
Condensate water can be drained directly onto the roof in rooftop
installations (where permitted) or onto a gravel apron in ground
level installations. Install a field--supplied 2--in. (50.8 mm)
condensate trap at the end of condensate connection to ensure
proper drainage. Make sure that the outlet of the trap is at least 1 in.
(25.4 mm) lower than the drain--pan condensate connection to
prevent the pan from overflowing (See Fig. 7). Prime the trap with
water. When using a gravel apron, make sure it slopes away from the
unit.
Connect a drain tube using a minimum of 3/4--in. PVC or 3/4--in.
copper pipe (all field--supplied) at the outlet end of the 2--in. trap.
Do not undersize the tube. Pitch the drain tube downward at a slope
of at least 1--in. for every 10 ft of horizontal run. Be sure to check
the drain tube for leaks.
TRAP
OUTLET
2" min.
1" min.
C00009
Fig. 7 -- Condensate Trap
Step 7—Install Flue Hood
The flue assembly is secured and shipped in the return air duct.
Remove duct cover to locate the assembly (See Fig. 9 and 10).
NOTE
: Dedicated low NOx models MUST be installed in
California Air Quality Management Districts where a Low NOx
rule exists.
These models meet the California maximum oxides of nitrogen
(NOx) emissions requirements of 40 nanograms/joule or less as
shipped from the factory.
NOTE
: Low NOx requirements apply only to natural gas
installations.
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury
or death.
The venting system is designed to ensure proper venting. The
flue hood assembly must be installed as indicted in this section
of the unit installation instructions.
!
WARNING
Install the flue hood as follows:
1. This installation must conform with local building codes and
with the National Fuel Gas Code (NFGC), ANSI Z223.1 (in
Canada, CAN/CGA B149.1, and B149.2) or NFPA
(National Fire Protection Association) latest revision. Refer
to Provincial and local plumbing or wastewater codes and
other applicable local codes.
48E
S
Содержание 48ES
Страница 15: ...15 A07230 Fig 15 208 230 1 60 Wiring Diagram 48ES...
Страница 16: ...16 A07232 Fig 16 208 230 3 60 Wiring Diagram 48ES...
Страница 17: ...17 A07231 Fig 17 460 3 60 Wiring Diagram 48ES...