INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Part
code
Parts name
Q’ty
A
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side
: Ø12.70 mm
One
each
B
Pipe insulating material
(polyethylene foam, 8 mm thick)
1
C
Putty, PVC tapes
One
each
Optional Installation Parts
• Secure the outdoor unit with
fi
xing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
Fixing bolt arrangement of outdoor unit
125 mm
108 mm
28 mm
320 mm
340 mm
600 mm
90 mm
Drain outlet
86 mm
102 mm
Ø25 mm
Air outlet
Air inlet
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
Batteries
Flat head
wood screw
Battery
cover
Flat head
wood screw
Flat head
wood screw
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Wireless remote control
Saddle
Extension drain hose
(Not available, provided
by installer)
The provided Remote Controller is a wireless
type, which also can be used as a wire.
Please see “How to Connect The Remote
Controller for Wired Operation”, in case of
wired control is required.
Shield pipe
(Attach to the front panel.)
Air
fi
lter
Hook
Installation plate
Hook
50 mm or more
300 mm or more
170 mm or more
600 mm or more
100 mm or more
100 mm or more
600 mm or more
600 mm or more
The
fl
are connection should be installed
outdoors.
Refrigerant piping
must be protected
from physical
damage.
Install a plastic
cover or equivalent.
Filter
8 mm thick heat resisting
polyethylene foam
Insulate the refrigerant pipes separately
with insulation, not together.
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Cut out a piece of SPACER from indoor
unit packaging box, roll it and insert
between the indoor unit and wall to tilt
the indoor unit for better operation.
For the rear left, bottom left and left piping
Wall
01_1124950113_EN.indd 6
01_1124950113_EN.indd 6
23/11/2563 BE 18:35
23/11/2563 BE 18:35
Содержание 42TVBA018
Страница 19: ...TH 2 2 R32 02_1124950113_TH indd 2 02_1124950113_TH indd 2 24 11 2563 BE 16 46 24 11 2563 BE 16 46...
Страница 33: ...MEMO 00_1124950113_Cover indd 3 00_1124950113_Cover indd 3 23 11 2563 BE 17 39 23 11 2563 BE 17 39...
Страница 34: ...MEMO 00_1124950113_Cover indd 4 00_1124950113_Cover indd 4 23 11 2563 BE 17 39 23 11 2563 BE 17 39...
Страница 35: ...00_1124950113_Cover indd 5 00_1124950113_Cover indd 5 23 11 2563 BE 17 39 23 11 2563 BE 17 39...
Страница 36: ...1124950113 00_1124950113_Cover indd 6 00_1124950113_Cover indd 6 23 11 2563 BE 17 39 23 11 2563 BE 17 39...