8
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the plastic for
cover hole as shown on
fi
gure
4
.
4. Insert control wire from rear side of remote controller as shown on
fi
gure
5
.
5. Fix control wire which arrange as shown on
fi
gure
6
and
7
to terminal
by provided screws (tighten
fi
rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on
fi
gure
8
.
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on
fi
gure
9
.
8. Mark and arrange hole for
fi
x below screw (Ø3.1×25L) as shown on
fi
gure
9
.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to
fi
x battery cover together with wall as
shown on
fi
gure
!
(tighten
fi
rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
Polyester sheet close hole
for insert control wire
* Terminals for wiring can be either on right (type A) or left (type B), depending on
the controller packed in carton.
Control wire
Type A
Type B
Terminal
Control wire
4
5
6
7
30 mm
10 mm
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
For remote controller
70 mm
5 mm
1
3
2
Screw
Screw cap
Control wire
Notch for wire out
Control wire
Terminal
Display unit
Screw
Front panel
* Wire size 28-22AWG
or 0.08-0.32 mm
2
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
*
Remark
: 1. Recommend to use double insulation lead wire for connect
remote control and air conditioner.
2. For wire operation, 1 remote control can control only 1 indoor
unit.
3. In wire operation, remote controller will return to initial
condition (PRESET, TIMER and CLOCK will return to
initial condition) when user shutdown power supply of air
conditioner.
Control wire
Hole for hang
remote controller
Remote controller
Type A
Type B
Control wire
Screw (Ø3.1×16L)
for hang remote
controller
Wall
Screw (Ø3.1×25L)
for
fi
x battery cover
Remote controller
8
9
!
Battery cover
Screw
Tighten
fi
rmly but not over
0.15 N·m (0.02 kgf·m)
Piping and Drain Hose Installation
* Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
Piping and drain hose forming
1. Die-cutting front panel slit
Cut out the slit on the left or right side of the front panel for the left or right
connection and the slit on the bottom left or right side of the front panel
for the bottom left or right connection with a pair of nippers.
Rear right
Rear left
Bottom left
Left
Bottom right
Right
Die-cutting
front panel slit
Changing
drain hose
Piping preparation
2. Changing drain hose
For leftward connection, bottom-leftward connection and rear leftward
connection’s piping, it is necessary to change the drain hose and drain
cap.
01_1124950113_EN.indd 8
01_1124950113_EN.indd 8
23/11/2563 BE 18:36
23/11/2563 BE 18:36
Содержание 42TVBA018
Страница 19: ...TH 2 2 R32 02_1124950113_TH indd 2 02_1124950113_TH indd 2 24 11 2563 BE 16 46 24 11 2563 BE 16 46...
Страница 33: ...MEMO 00_1124950113_Cover indd 3 00_1124950113_Cover indd 3 23 11 2563 BE 17 39 23 11 2563 BE 17 39...
Страница 34: ...MEMO 00_1124950113_Cover indd 4 00_1124950113_Cover indd 4 23 11 2563 BE 17 39 23 11 2563 BE 17 39...
Страница 35: ...00_1124950113_Cover indd 5 00_1124950113_Cover indd 5 23 11 2563 BE 17 39 23 11 2563 BE 17 39...
Страница 36: ...1124950113 00_1124950113_Cover indd 6 00_1124950113_Cover indd 6 23 11 2563 BE 17 39 23 11 2563 BE 17 39...