CONFORMITY

This unit complies with European directives:

• Low tension directive 2014/35/UE

• Electro-magnetic compatibility 2014/30/UE;.

SYMBOLS

The pictograms in the next chapter provide  the necessary information for correct, safe use of the machine in a rapid, unmistakable 

way

Editorial pictograms

U

 User

 

-

Refers to pages containing instructions or information for the user.

I

 Installer

 

-

Refers to pages containing instructions or information for the installer

S

 Service

 

-

Refers to pages containing instructions or information for the installer TECHNICAL CUSTOMER SERVICE.

Safety pictograms

 Generic danger

 

-

Signals to the personnel that the operation described could cause physical injury if not performed according to the safety rules.

 Danger of high voltage

 

-

Signals to the personnel that the operation described could cause electrocution if not performed according to the safety rules.

 Danger due to heat

 

-

Signals to the personnel that the  operation described could cause burns if not performed according to the safety rules.

 Do Not

 

-

Refers to actions that absolutely must not be performed.

The illustrations in this document are for illustrative purposes only and not part of any offer for sale or contract. The manufacturer reserves the right to change the design 

at any time without notice.

Содержание 42SIC

Страница 1: ...Original document INSTALLATION OPERATION AND M A I N T E N A N C E I N S T R U C T I O N S 42SIC 42SIR 42SIN 42SIl...

Страница 2: ...CHNICAL CUSTOMER SERVICE Safety pictograms Generic danger Signals to the personnel that the operation described could cause physical injury if not performed according to the safety rules Danger of hig...

Страница 3: ...n 42SIC or 42SIN 7 2 7 Mounting front grill safety support 42SIC 7 2 8 Horizontal or ceiling installation 42SIC or 42SIN 8 2 9 Hydraulic connections 8 2 10 Condensation discharge 9 2 11 Filling the sy...

Страница 4: ...odically open the windows to ensure a correct change of air This instruction leaflet is an integral part of the unit and consequently must be kept carefully and must ALWAYS accompany the unit even whe...

Страница 5: ...de in case of ceiling installation the airflow is not directed towards persons 2 2 Installation modes The following descriptions of the various mounting phase and the relative designs refer to a versi...

Страница 6: ...efer to the individual instructions leaflets supplied and the relative manual for the mounting of the feet Using the paper template trace the position of the two fixing brackets on the wall Use a suit...

Страница 7: ...lation of 42SIR low height with cabinet units in horizontal position is prohibited Carefully check the inclination of the exhaust pipe Any counterslope of the discharge line can cause water leakage B...

Страница 8: ...zes 29 49 69 89 99 Pipeline diameter mm 14 14 16 18 20 The choice and sizing of the hydraulic lines must be made by an expert who must operate according to the rules of good technique and the laws in...

Страница 9: ...ld interfere with the normal outflow If there is a height difference that could interfere with the outflow of the condensation a pump must be mounted in a vertical installation mount the pump under th...

Страница 10: ...sition take a screwdriver and act on the highest breather of the battery for appliances installed in a horizontal position act on the highest positioned breather for the 4 pipe versions act on the hig...

Страница 11: ...the risk of burns Do not use abrasive sponges or abrasive or corrosive detergents to avoid damaging the painted surfaces When necessary clean the outer surfaces of the Air Leaf cooler convector with...

Страница 12: ...m cleaner wash the filter with running water without using detergents or solvents and leave to dry Remount the filter on the cooler convector fig 32 ref A taking care to insert the lower flap into its...

Страница 13: ...rt B C B tabs C slots For the versions with a mobile panel rest it in its position parallel to the front panel and press until it is blocked 2 17 Energy saving tips Always keep the filters clean when...

Страница 14: ...s of the motor and thefree rotation of the fan The micro switch that stops the ventilation when the filter grill is opened does not close correctly Check that by closing the grill the micro switch con...

Страница 15: ...15...

Страница 16: ...der No 10547 09 2019 Supersedes order No New Manufactured by Carrier SCS Montluel France Manufacturer reserves the right to change any product specifications without notice Printed in the European Uni...

Отзывы: