Carrier 42PHQ Series Скачать руководство пользователя страница 8

GB - 7

42PHQ ...P 

Installation

Routing the drain hose and refrigerant
piping

• Tie together the refrigerant pipe, the drain hose, and the

electrical connection cord.

• Route the refrigerant piping in the required direction, and bind

the drain hose and the electrical connection cord together with
fastening tape.
The drain hose should be at the bottom.

• For left-hand piping, fit the pipes and the wiring into the recess at

the back of the unit.

Installing the indoor unit body to the wall
hanging bracket

• Pass the pipes through the wall sleeve and then hook the

indoor unit body on top of the wall hanging bracket.

• For left-hand piping, hang the unit on top of the wall hanging

bracket and incline the unit using a tool such as a screwdriver
set between the middle area of the body and bottom right of
the wall hanging bracket.
Connecting the pipe can be done more easily if the unit is
inclined.

• Fix the bottom part of the unit to the wall hanging bracket, by

pushing it carefully unit the two bracket hooks fit into the
marked places at the base of the unit (a click will be heard).

NOTE:

• Do not crush or kink the indoor piping. Avoid sharp bends with a

bend radius of less than 100 mm.

• Do not bend the same part of the pipe too often.

• Do not remove the flare nut from the indoor unit pipe until the

piping is connected.

• The recommended bending of the drain hose is shown.

Indoor unit
piping

Left-hand piping

Bind with
fastening tape

Drain hose

Indoor unit piping

Drain hose

Connection cord

 

Wall hanging
bracket

Hook

 

Hole

Model

A

B

007, 009

300

        220

012, 014

300

        220

018, 024

270

        195

[mm]

Содержание 42PHQ Series

Страница 1: ...42PHQ P INSTALLATION MANUAL L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1...

Страница 2: ...ions and weight 2 Nominal data 2 Operating limits 2 Minimum clearances 3 Material supplied 3 General information 4 Warnings avoid 5 Installation 6 7 Refrigerant connections 8 Check 9 Electrical connec...

Страница 3: ...nal data Unit is not suitable for operation in laundry premises For sizing of power supply wires and delay type fuses refer to the outdoor unit installation instructions Mod 007 009 012 014 018 024 A...

Страница 4: ...ld supplied items are required to complete the installation Name Specification 007 009 Connection pipe 3 8 9 52 mm Gas 1 4 6 35 mm Liquid 012 014 018 024 1 2 12 70 mm Gas 1 4 6 35 mm Liquid Wall sleev...

Страница 5: ...onsisting of two units manufactured by Carrier Consult the factory or a qualified system engineer prior to connecting this unit to any other manufacturer s outdoor unit Coupling units which have diffe...

Страница 6: ...ondensate dripping Flattening or kinking the refrigerant pipes or condensate pipes Excessive height difference between outdoor and indoor units see installation manual of outdoor unit Unnecessary turn...

Страница 7: ...he bracket and the wall Check that the wall hanging bracket does not move This can cause noise during operation If the unit is removed from the wall hanging bracket after installing it onto the wall r...

Страница 8: ...e the unit using a tool such as a screwdriver set between the middle area of the body and bottom right of the wall hanging bracket Connecting the pipe can be done more easily if the unit is inclined F...

Страница 9: ...to ISO1337 degreased and deoxidized suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used Fla...

Страница 10: ...screws After installation if there is a significant gap between the unit and wall it can be adjusted by securing the body to the wall hanging bracket using 2 screws Screw holes can be only seen after...

Страница 11: ...009 012 014 to the indoor unit sizes 018 024 to the outdoor unit Make electrical connections between units prior to proceeding to mains supply unit connection Before proceeding with the connection to...

Страница 12: ...l Cooling only 42PHQ007P 009P 012P 014P 2 Minimum connection wire size Minimum connection wire size between for power supply mm2 indoor and outdoor unit mm2 Models GND L N N Y O W2 42PHQ007P 009P 1 5...

Страница 13: ...2P 014P 2 3 Minimum connection wire size Minimum connection wire size between for power supply mm2 indoor and outdoor unit mm2 Models GND L N N Y O W2 42PHQ007P 009P 1 5 1 5 1 5 1 5 1 5 42PHQ012P 014P...

Страница 14: ...default value of temperatures in Degrees Celsius C to the new value Degrees Fahrenheit o F Press button repeatedly until rc is displayed Press either the or button to change the default value of Heat...

Страница 15: ...ress button to leave the configuration menu Fault code Once a failure occurs with the indoor unit in operation the green LED flashes at intervals of 0 5 seconds The fault code is deduced from the numb...

Страница 16: ...Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice December 2003 Printed in Korea 42KU5A54040...

Отзывы: