Safety Precautions

2

Read Safety Precautions Before Installation 

Incorrect installation due to ignoring instructions can cause serious damage or injury. 

The seriousness of potential damage or injuries is classified as either a 

WARNING 

or 

CAUTION. 

 

 

 WARNING

•  Carefully read the Safety Precautions before installation.
• 

In certain functional environments, such as kitchens, server rooms, etc., the use of specially 
designed air-conditioning units is highly recommended. 

•  Only trained and certified technicians should install, repair and service this air 
    conditioning unit.

Improper installation may result in electrical shock, short circuit, leaks, fire or other damage to 
the equipment and personal property. 

•  Strictly follow the installation instructions set forth in this manual.

Improper installation may result in electrical shock, short circuit, leaks, fire or other damage to 
the equipment.

•  Before you install the unit, consider strong winds, typhoons and earthquakes that might affect 
     your unit and locate it accordingly. Failure to do so could cause the equipment to fail. 

 

•  After installation, ensure there are no refrigerant leaks and that the unit is operating properly. 
    Refrigerant is both toxic and flammable and poses a serious health and safety risk.

Note about Fluorinated Gasses

1.

   

This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas 
and the amount, please refer to the relevant label on the unit itself. 

2.

   

Installation, service, maintenance and repair of this unit must be performed by a certified 
technician. 

3.

 

Product uninstallation and recycling must be performed by a certified technician.

4.

   

If the system has a leak-detection system installed, it must be checked for leaks at least every 12 
months.

5.

   

When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.

Failure to observe a warning may result in death. The appliance must be installed in 
accordance with national regulations. 

Failure to observe a caution may result in injury or equipment damage.

 

WARNING

 

CAUTION

Содержание 42/38SHDS050

Страница 1: ...ing your new air conditioning unit Make sure to save this manual for future reference This manual only describes the installation of outdoor unit When installing the indoor unit refer to the installat...

Страница 2: ...cautions 05 Outdoor Unit Installation 12 a Outdoor Unit Installation Instructions 12 b Outdoor Unit Types and Speci cations 13 c Notes on Drilling Hole in Wall 14 Drainpipe Installation 15 Table of Co...

Страница 3: ...ping Connection 17 A Notes on Pipe Length and Elevation 17 B Refrigerant Piping Connection Instructions 18 Wiring 20 a Outdoor Unit Wiring 20 b Indoor Unit Wiring 21 23 Air Evacuation 25 a Evacuation...

Страница 4: ...ement sometimes the pipe connections need the transfer connector to install on the outdoor unit 11 Transfer connector 9 52 12 7 indoor unit used for multi type models only NOTE Pipe size di er from ap...

Страница 5: ...strong winds typhoons and earthquakes that might a ect your unit and locate it accordingly Failure to do so could cause the equipment to fail After installation ensure there are no refrigerant leaks a...

Страница 6: ...1 2 3 4 5 MC MC 6 7 Install the indoor unit Page 7 INSTALLATION ORDER Install the outdoor unit Page 13 Install the drainpipe Page 15 Evacuate the refrigeration system Page 25 Connect the wires Page 20...

Страница 7: ...meets the following requirements There is enough room for installation and maintenance There is enough room for the connecting pipe and drainpipe The ceiling is horizontal and its structure can sustai...

Страница 8: ...mension and air outlet size Air inlet size Air lter Position of descensional ventilation opening and size of mounted hook Air lter Electric control box Table 4 1 unit mm inch MODEL Btu h Outline dimen...

Страница 9: ...re the same size before moving on 2 Carry out the pipe and line operation in the ceiling after nishing the installation of the main body While choosing where to start the operation determine the direc...

Страница 10: ...all be added to reduce the noise for special requirement 1 Install the lter optional according to air inlet size 5 Please refer to the following static pressure to install Change the fan motor static...

Страница 11: ...slightly di erent from the air conditioner you purchased The actual unit shall prevail Step 5 Fresh air duct installation Dimension Duct joint for fresh air 125mm 4 92 160mm 6 3 MODLE 18 60 Step 6 Mot...

Страница 12: ...or unit may not exceed the maximum allowable pipe length If possible DO NOT install the unit where it is exposed to direct sunlight If possible make sure the unit is located far away from your neighbo...

Страница 13: ...5 1 Length Speci cations of Split Type Outdoor Unit unit mm inch Refer to Fig 5 4 5 5 and Table 5 1 A B D Fig 5 4 Outdoor Unit Dimensions W x H x D Mounting Dimensions Distance A Distance B 946x810x41...

Страница 14: ...cing the front of the unit 4 Connect a drain hose extension not included to the drain joint to redirect water from the unit during heating mode NOTE Make sure the water drains to a safe location where...

Страница 15: ...lead to water damage If the drainpipe is bent or installed incorrectly water may leak and cause a malfunction of the water level switch In HEAT mode the outdoor unit will discharge water Ensure that...

Страница 16: ...r drainage See Fig 6 5 Place the protective wall cu in the hole This protects the edges of the hole and will help seal it when you nish the installation process Wall Indoor Outdoor 12mm 0 5 inch Fig 6...

Страница 17: ...frigerant circuit Contamination in the system may cause poor operating capacity high pressure in the refrigeration cycle explosion or injury Ventilate the area immediately if there is refrigerant leak...

Страница 18: ...1 Make sure that the pipe is cut at a perfect 90 angle Refer to Fig 7 2 for examples of bad cuts Oblique Rough Warped 90 Fig 7 2 Step2 Remove burrs Burrs can a ect the air tight seal of refrigerant pi...

Страница 19: ...a torque wrench to tighten the are nut according to the torque values in table 7 5 NOTE Use both a spanner and a torque wrench when connecting or disconnecting pipes to from the unit Fig 7 8 CAUTION...

Страница 20: ...sconnects all poles with contact gap of a least 3mm 0 118 DO NOT modify the length of the power cord or use an extension cord CAUTION Connect the outdoor wires before connecting theindoor wires Make s...

Страница 21: ...or connection a Using wire strippers strip the rubber jacket from both ends of signal cable to reveal about 15cm 5 9 of the wires inside b Strip the insulation from the ends of the wires c Using wire...

Страница 22: ...nditioning unit is o perform the next steps Press the button COPY long Press the button or to select the AF Press the button CONFIRM Then the air conditioning unit will start the fan operation for air...

Страница 23: ...System power supply from outdoor unit Power Speci cations e Page 23 f Wiring NOTE...

Страница 24: ...the manifold gauge Keep the High Pressure side closed 4 Turn on the vacuum pump to evacuate the system 5 Run the vacuum for at least 15 minutes or until the Compound Meter reads 76cmHG 1x105Pa 6 Clos...

Страница 25: ...osions or accidents Ensure that the appropriate refrigerant is used Refrigerant containers must be opened slowly Always use protective gear when charging the system DO NOT mix refrigerants types Some...

Страница 26: ...emperature is being registered correctly d Ensure the indicators on the remote control and the display panel on the indoor unit work properly e Ensure the manual buttons on the indoor unit works prope...

Страница 27: ......

Отзывы: