Restrictions to connection may be imposed by the supply authority on the use of 

   equipment  if the actual system impedance at the interface point on the user s premises 
   exceeds  0.12ohm
.

The unit complies with low-voltage (EEC/73/23) and electromagnetic compatibility

   (EEC/89/336) directives.

Carefully recover refrigerant within this unit before final disposal or when servicing.

   Never vent refrigerant to atmosphere.

ALL of the manufacturing and packageing material used for your new appliance are

   compatible with the environment and can be recycled.

Disconnect the mains power supply switch and wait over 2 minutes without toughing

   any internal parts of the unit before servicing the system or handing any internal parts 
   of the unit.

     

All field electrical connections are the responsibility of the installer

.

If not using plug, ensure that mains supply connection is made through a switch that 

  disconnects

 

all poles, with contact gap of a least 3mm

.

There are some kinds of cord clamp in the accessory parts If cord clamp is not used as

   specified , the power cable and interconnection wire will be damaged. 

The equipment contains R-407C refrigerant, a substance that is not depleting the ozone

   layer but

 

must be disposed of in a proper manner. When disposing of the unit after its 

   operational life,remove it carefully.

Check that the impedance of the mains power supply is in conformance with the unit 

  power

 

input indicated in the electric (EN 61000-3-11)

.

Control batteries contain polluting elements.When exhausted they must be disposed

   of according to local requirements.

After the installation thoroughly test system operation and explain all system 

  functions to the owner.

Leave this manual with the owner for consultation during future periodic maintenance.

Use this unit only for factory approved applications:the unit cannot be used in laundry 

  or steam pressing premises.

Follow all current national safety code requirements. In particular ensure that a property 

  sized and connected ground  wire is in place.

Check that voltage and frequency of the mains power supply are those required for the

   unit to be installed;the available power must be adequate to operate any other possible
   appliances connected to the same line.

The manufacturer declines any liability for damage resulting  from modifications or

   errors in the electrical or refrigerant connections.

Failure to observe the installation instructions or use of the  unit under conditions other

   than those indicated in operating limits , will immediately void the unit warranty.

Failure to observe electric safety codes may cause a fire hazard in case of short circuits.

Inspect equipment for damage due to improper transportation or handing :file an 

  immediate claim with the shipping company.Do not install or use damaged units.
 

42HQE009(012)/38YE009(012)

GB-2

Содержание 38YE009(012)

Страница 1: ...R 407C GB INSTALLATION MANUAL I MANUALE DI INSTALLAZIONE F MANUEL D INSTALLATION S INSTALLATIONSMANUAL E MANUAL DE INSTALACION GR 42HQE009 012 38YE009 012...

Страница 2: ...I F ITALIANO E Acondlclonador de aire split unidad interlor Hi Wall Climatizzatori split unit interna Hi Wall FRANCAIS Climatiseur split unit int rieure Hi Wall ESPANOL GR S SVENSKA Split system Hi Wa...

Страница 3: ...ed to a strong wind Aplace that is dry and ventilated A place can bear the weight of the outdoor unit and where the outdoor unit can be held in the horizontal position A place which does not allow an...

Страница 4: ...efully Check that the impedance of the mains power supply is in conformance with the unit power input indicated in the electric EN 61000 3 11 Control batteries contain polluting elements When exhauste...

Страница 5: ...tion The outdoor unit should not be exposed to strong wind Fix the outdoor unit with 10 or 8 anchor bolts air outlet air inlet A B Remote controller Mounting screw B ST2 9x10 C H Remote controller hol...

Страница 6: ...lls make 6mmdia holes in the wall Insert clip anchors for appropriate mounting screws 3 Fix the installation plate on the wall 1 As diagram above determine the pipe hole position using the installatio...

Страница 7: ...iping install the piping as shown Bend the conn ective pipe to be laid at 43mm height or less from the wall 3 Fix the end of the connective pipe Refer to Tightening Connection in REFRI GRANT PIPING CO...

Страница 8: ...made by lifting the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall Then move the ind...

Страница 9: ...lowing installation conditions do apply 1 The power connection for the air conditioner has to be done at the main power distribution The distribution has to be of an low impedance normally the require...

Страница 10: ...he installation bracket should accord with technique requir ement in the installation bracket diagram Strong wind 1 OUTDOOR INSTALLATION PRECAUTION Mod Amm 38YE009 012 B mm C mm D mm E mm F mm A B C D...

Страница 11: ...ring Regulation All wiring must comply with local and national electrical codes and be installed by qualified and skilled electrician Cover Screw Cooling heating type Terminals on the outdoor unit Wir...

Страница 12: ...lightly loose the flare nut of the packed valve on the gas pipe side and check that the air is entering Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus 5 A...

Страница 13: ...dotto pu comportare senza preavviso cambiamentio modifiche aquanto descritto La recherche permanentede perfectionnement duproduit peut n cessiter des modificationsou changements sans pr avis El fabric...

Отзывы: