– 49 –
FILE NO. SVM-07018
9-3-5. Gas leak test
Fig. 9-3-10
•
Check the flare nut connections for the gas leak
with a gas leak detector or soap water.
9-3-6. Test operation
To switch the TEST RUN (COOL) mode, push
TEMPORARY button for 10 sec.
(The beeper will make a short beep.)
Fig. 9-3-11
9-3-7. Auto restart setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
Information
The product was shipped with Auto Restart function
in the off position. Turn it on as required.
<How to set the auto restart>
•
Press and hold down the TEMPORARY button for
about 3 seconds. After 3 seconds, the electronic
beeper makes three short beeps to tell you the Auto
Restart has been selected.
•
To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function of
the Owner’s Manual.
Check places
for outdoor unit
Valve cover
Check places for
indoor unit (Flare
nut connection)
Electric parts
cover
TEMPORARY button