31
-
2) Defrost operation
Operation of the compressor is stopped once,
turn off power coupler for 4-way valves after
10 seconds, and then exchange the 4-way
valves.
After 20 seconds, restart operation of the
compressor. Turn off the outdoor fan just when
the compressor stopped.
If temperature of the indoor heat exchanger
lowered than 38°C, stop the indoor fan.
3) Defrost reset
Resetting operation from defrost to heating is
performed when anyone of the following
conditions is satisfied.
a. Temperature of the outdoor heat exchanger
rose to +8°C or higher.
b. A status that temperature of the outdoor
heat exchanger is +5°C or higher continued
for 80 seconds.
c. Defrost operation continued for 15 minutes.
In resetting defrost operation, the compressor
stops for 50 seconds if defrost has started under
condition a. to c. in item1), but the compressor is
reset to heating operation keeping operated if
defrost has started under condition d. in item 1).
(5) Louver control
When the compressor is turned off by high-temp.
release control, the vertical air flow louvers close
once and then return to the position of previous
time.
(6) ECONO operation control.
When the [ECO] button is pushed, ECONO
operation is performed by restraining air flow and
compressor motor speed.
1) The indoor fan speed is controlled within L-
as maximum speed.
2) Compressor motor speed is controlled by the
difference value of room temperature and set
temperature as shown in Fig. 8-2-8
The different value of room temperature and
set temperature are separated to A, B and
C zone. Then compressor motor speed in each
zone are controlled by different speed.
After 30 minutes passed, the different value of
room temperature and set temperature is
separated zone again by more different value
than before. Then compressor motor speed
after 30 minute passed is lower than before by
the same different value of room temperature
and set temperature.
30 Min
Time
38YVE009
21
rps
21
-
37
rps
37
rps
A
C
-11.0
-5.0
-5.5
A-Zone
B-Zone
C-Zone
Room
te
pm
. - Set t
em
p.
(
o
C)
0.0
-0.5
-1.0
-1.5
-2.0
-2.5
Zone
B
-11.5
A-Zone
B-Zone
C-Zone
Fig. 8-2-8
38YVE012
20
rps
20
-
45
rps
45
rps
Содержание 38NYV009E
Страница 16: ...C L C L 3 2 Outdoor Unit FILE NO SVM 07018 15...
Страница 18: ...4 2 Outdoor Unit 38NYV009E 38NYV012E FILE NO SVM 07018 17...
Страница 86: ...FILE NO SVM 03008 87...