8-5-4. Wiring connection
1.
Remove the valve cover from the outdoor unit.
2.
Connect the connecting cable to the terminal as
identified with their respective matched numbers on
the terminal block of indoor and outdoor unit.
3.
When connecting the connecting cable to the
outdoor unit terminal, make a loop as shown in the
installation diagram of indoor and outdoor unit, to
prevent water coming in the outdoor unit.
4.
Insulate the unused cords (conductors) from any
water coming in the outdoor unit. Proceed them so
that they do not touch any electrical or metal parts.
<Stripping length of connecting cable>
Fig. 8-5-9
CAUTION
•
Wrong wiring connection may cause some
electrical parts burn out.
•
Be sure to comply with local codes on running
the wire from indoor unit to outdoor unit (size of
wire and wiring method etc.)
•
Every wire must be connected firmly.
NOTE
•
Wire type: H07 RN-F or 245 IEC66 (2.0 mm
2
or
more)
8-6. How to Set Remote Control Selector
Switch
When two indoor units ae installed in seperated rooms,
there is no need to change the selector switch.
<Remote control selector switch>
When two indoor units are installed in the same
room or the adjacent two rooms, they may be
controlled simultaneously with a single remote
control. To prevent this, set either unit and its
remote control to B setting. (Both units are set to A
setting before shipment.)
The remote control signal is not recived when the
indoor unit setting is different from the remote
control one.
·
·
To separate using of remote control for each indoor
unit in case of 2 air conditioner are installed nearly.
<Remote control A-B Selection>
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn
2. Point the remote control at the indoor unit.
3. Push and hold CHK
•
button on the Remote
Control by the tip of the pencil. "00" will be
4. Press during pushing CHK
•
. "B" will show
on the display and "00" will disappear and the
MODE
air conditioner will turn OFF. The Remote
the are conditioner ON.
shown on the display.
Control B is memorized.
Note:
1. Repeat above step to reset Remote Control
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory
to be A.
is A.
1(L ) 2(N) 3 4
100 mm
10 mm
10 mm
50 mm
Terminal block
Connecting cable
Terminal screw
screw
Cord clamp
Earth line
Earth line
Connecting cable