– 27 –
FILE NO. SVM-10036
8
-2. Installation Diagram of Indoor and Outdoor Units
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
For the rear left and left piping
Wall
Insulate the refrigerant pipes separately
with insulation, not together.
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
The auxiliary piping can be connected to
the left, rear left, rear right bottom
right or bottom left.
Rear
right
Bottom
right
Rear
left
Bottom left
Left
6 mm thick heat resisting
polyethylene foam
1
Shield pipe
Hook
Installation
plate
Hook
47
mm or more
120
mm or more
120
mm or more
100 mm or more
45
mm or more
400
mm or more
Saddle
Vinyl tape
Apply after carrying
out a drainage test.
1
00 m
m or m
ore
Extension
drain hose
(Not available,
provided by
installer)
600 mm or more
5
Active Carbon
Cleaning filter
Air filter
(Attach to the front panel.)
8
Pan head
wood screw
4
Remote control holder
3
Batteries
2
Wireless remote control
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (
−
) positions.
3 Batteries
2 Wireless remote controller
A
C
L