PARTS LIST

Table 1—Parts List

PART NO.

PART NAME

QTY.

1

Outdoor unit

1

-

Literature package including installation instructions and warranty

1

-

Grommet to secure the outdoor unit (helps with vibration prevention during unit operation)

4

-

Drain Joint

1

-

Drain Hose

1

■ Outdoor

 1

A150766

Fig. 1

 - 

Parts List

NOTE:  

− If the outdoor unit is higher than the indoor unit, prevent rain from flowing into the indoor unit along the connection pipe by making

a downward arc in the connection pipe before it enters the wall to the indoor unit. This ensures that rain drips from the connection
pipe before it enters the wall.

− Piping and the interconnecting wiring are field supplied.

− The illustration above is only a sketch. Different models may be slightly different.

The following units are covered in these installation instructions.

Table 2—Unit Sizes

Cooling Only

SYSTEM TONS

BTUh

VOLTAGE - PHASE

OUTDOOR MODEL

0.75

9,000

115-1

38MHRC09A--1

1.00

12,000

115-1

38MHRC12A--1

0.75

9,000

208/230-1

38MHRC09A--3

1.00

12,000

208/230-1

38MHRC12A--3

1.50

18,000

208/230-1

38MHRC18A--3

2.00

24,000

208/230-1

38MHRC24A--3

Heating Pump

0.75

9,000

115-1

38MHRQ09A--1

1.00

12,000

115-1

38MHRQ12A--1

0.75

9,000

208/230-1

38MHRQ09A--3

1.00

12,000

208/230-1

38MHRQ12A--3

1.50

18,000

208/230-1

38MHRQ18A--3

2.00

24,000

208/230-1

38MHRQ24A--3

Содержание 38MHR series

Страница 1: ...ual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS LIST 3 SYSTEM REQUIREMENTS 4 DIMENSIONS OUTDOOR 5 CLEARANCES OUTDOOR 8 INSTALLATION TIPS 9 OUTDOOR UNIT INSTAL...

Страница 2: ...hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in...

Страница 3: ...rips from the connection pipe before it enters the wall Piping and the interconnecting wiring are field supplied The illustration above is only a sketch Different models may be slightly different The...

Страница 4: ...il connected Wiring All wires must be sized per NEC National Electrical Code or CEC Canadian Electrical Code and local codes Use the Electrical Data table MCA minimum circuit amps and MOCP maximum ove...

Страница 5: ...88 6 40 2 Heat Pump System Size Height H in mm Width W in mm Depth D in mm Weight Net lbs kg 9K 115 21 85 555 30 31 770 11 81 300 61 5 27 9 12K 115V 21 85 555 30 31 770 11 81 300 65 0 29 5 9K 208 230V...

Страница 6: ...800 20 24 514 21 81 554 2 36 6 0 3 37 8 5 5 13 39 340 0 47 1 2 12 24 311 12 80 325 13 11 333 2 76 7 0 H H1 H2 D1 D2 D3 2 43 6 1 8 4 17 1 06 0 87 2 2 R 0 79 R 20 R 0 24 R 6 2 43 6 1 6 D W W1 W2 B1 B2 A...

Страница 7: ...7 DIMENSIONS OUTDOOR CONT Unit inch mm Fig 4 Size 24K...

Страница 8: ...C E A07894 Fig 5 Outdoor Unit Clearance Table 5 Outdoor Unit Clearance Dimensions UNIT MINIMUM VALUE in mm A 24 610 B 24 610 C 24 610 D 4 101 E 4 101 NOTE The outdoor unit must be mounted at least 2i...

Страница 9: ...ntaminants to avoid damaging the refrigerant system Avoid sags in the suction line to prevent the formation of oil traps Insulate each tube with a minimum 3 8 in 10 mm wall thermal pipe insulation Ins...

Страница 10: ...malfunction A fire hazard may also exist Therefore ensure all wiring is tightly connected S No wire should be allowed to touch the refrigerant tubing compressor or any moving parts S Disconnecting mea...

Страница 11: ...ble limits of the voltage range at which the unit will operate satisfactorily LEGEND FLA Full Load Amps MCA Minimum Circuit Amps MOCP Maximum Over Current Protection RLA Rated Load Amps CONNECTION DIA...

Страница 12: ...acuum Method The deep vacuum method requires a vacuum pump capable of pulling a vacuum of 500 microns and a vacuum gage capable of accurately measuring this vacuum depth The deep vacuum method is the...

Страница 13: ...r unit s problems If possible always check the diagnostic codes displayed on the indoor unit first The diagnostic codes displayed on the outdoor units are listed on Table 10 Table 10 Unit Diagnostic G...

Страница 14: ...BDP S 7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No IM 38MHR 01 Replaces N...

Отзывы: