
7. OPERATION DESCRIPTION
7-1-1. Louver control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button is
stored in the microcontroller, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [
SWING
] button is pressed
again
,
it stops
swinging.
7-1. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses
AC motor for an indoor fan. The AC motor drive
circuit is mounted in the indoor unit. And electrical
parts which
driving
the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
−
14
−
The air conditioner is controlled by the controller
mounted in the indoor unit. The controller operates all
components based on the commands transmitted from
the remote control and the feedback data of the sensor
is as follow:
•
The temperature measurement at the air inlet of
the indoor heat exchanger by the indoor
temperature sensor
•
The temperature measurement at the indoor
heat exchanger by the indoor heat exchanger
temperature sensor
•
Indoor fan motor operation control
•
Louver motor control
•
LED display control
•
Outdoor fan motor operation control
•
Compressor operation control
•
Receiving the information of the operation
status and judging the information or the
indication of errors
FILE NO. SVM-05003
•
4-WAYS-VALVE operation control
(Heat pump model only)
Cooling
UH
H
M
L
L-
UL
SL
OPERATION
Dry
M
L
L-
UL
SL
MODE
Heat
UH
H
M
L
L-
UL
SL
rpm
13
0
0 1
25
0 12
0
0 1
10
0 1000
9
0
0
800 750
700 650
Air flow volume (m
3
/h)
6
3
0 6
1
0
57
0
52
0 460 4
0
0 340 310 280 250
42HNR010
Series
Model
42HNR012
Series
rpm
Air flow volume (m
3
/h)
1350 1300 1150 1100 1050 10
2
0 950 900 850 750
650 630 550 520 490 4
7
0 430 400 370 310
800
340
700
280
FAN TAP
Note : Under some function of setting. The fan motor is controlled automatically.
Then LOW+ = LOW + MED and MED+ = MED + HIGH
2
Table 7-1-1
2
7-1-2. Indoor fan control (AC Fan motor)
(1) The indoor fan is operated by the stepless speed
change AC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in
three steps
(LOW, MED,
and HIGH).
If AUTO mode is selected, the fan
motor speed is
automatically controlled by the
difference between
the preset temperature and
the room temperature.