12
–
FILE NO. SVM-05003
5-2. 42HNR010-713 / 38HNR010-713
Indoor unit
Cross flow fan
Cooling
Heating
4-way valve
Heating Cooling
Compressor
Heat exchanger
Propeller fan
Outdoor unit
PH180X1C-4DZDN3
Cooling
Heating
Mark ( ) means check points of Gas Leak.
O.D.:9.52 mm
O.D.:6.35 mm
Cooling
Heating
Packed valve
(
∅
9.52)
Packed valve
(
∅
6.35)
0.39 m
(Connecting pipe)
∅
9.52
0.49 m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R22 : 0.76 kg.
Capillary tube
∅
1.5 x 1000
s
Accumulator
Heat exchanger
Ambient temp.
conditions DB/WB
(
°
C)
Indoor
Outdoor
Standard
1.65
40.0
High
20/15
7/6
Heating
Overload*1
2.00 ~ 2.40
52.0 ~ 59.0
Low
27/
–
24/18
Low temperature
1.40
35.0
High
20/
–
–
10/
–
10
Standard 0.50 12.0 High 27/19 35/24
Cooling Overload 0.60 15.0 High 32/23 43/26
Low temperature 0.45 5.0 Low 21/15 21/15
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (
°
C)
Fan speed
(indoor)
50Hz
Note
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
*1
•
During heating overload operation, a value for the high temperature limit control operation is included.