39
62-11646
P
RETRIP
I
NSPECTION
- C
ONTINUED
IMMEDIATELY AFTER STARTING ENGINE
Visually check fuel lines and filters for leaks
Visually check oil lines and filters for leaks
Visually check coolant hoses for leaks
Visually check exhaust system for leaks
Verify correct air flow of condenser fan*
* Place a small rag in front of the condenser coil, the rag should hold. If the rag blows
away it means that the fan is rotating in reverse.
AFTER 15 MINUTES OF OPERATION
Initiate defrost and allow to terminate automatically, refer to
Check defrost drain line for blockage and proper water flow
PRETRIP
Initiate Pretrip, refer to
List any Pretrip alarms
FINAL
Enter trip start in micro, refer to
COMMENTS / NOTES