14-12
9/24/01
0: FXS Loop or Ground Start
1: FXS Ground Start
2: FXS Loop Start
3: FXO Loop or Ground Start
4: FXO Ground Start
5: FXO Loop Start
6: E&M Immediate Start
7: E&M Wink Start
8: E&M Wink Start ANI/DNIS
9: E&M DPT
type ............... Display DNI Channel Type
s:c [n] opt ...... Set Channel Type for [n] channels from s:c
clear
-- for data or bypass
voice
-- for voice signaling
dialout .............. Display/Set dialout alarm enables
all on|off ......... Set all alarm enabless
pager .............. Display/Set pager device strings
““ ““ ............ Disable pager device
“phone” “msg” .... Dial phone and msg (blanks ignored)
printer ............ Display/Set printer device strings
““ ““ ............ Disable printer device
“phone” “notify” . Dial phone, report for “notify”
“DIRECT” “notify” Direct connect report for “notify”
sys ................ Display/Set system alarms
power
on|off .. Hard reset or power on detected
brownout on|off .. Brown out detected
reset
on|off .. Soft reset detected
vn ................. Display/Set alarm enables for V.35 #n
rts
on|off .. Loss of V.35 RTS
llb
on|off .. Local Loop Back detected
v54
on|off .. Remote V.54 Loop Back detected
dn .....................Display/Set alarm enables for ds1 #n
carrier
on|off .... Loss of carrier detected
csuloop
on|off .... CSU loop code received
unframed on|off .... Unframed, all 1’s received
sync
on|off .... Loss of sync
yellow
on|off .... Yellow alarm received
bpv
on|off .... BPVs exceed 1544 in 15 min period
ses
on|off .... SES exceed 10 in 15 min period
unavail
on|off .... Unavailable seconds in 15 min period
fdlline
on|off .... FDL line loop request received
fdlpay
on|off .... FDL payload loop request received
ds1 [n|all] .......... Display/Set DS1 n=1..2 or all DS1s
circuitid “id” ..... DS1 Circuit ID
csu ................ Set DS1 CSU
off .............. Do not respond to CSU code
on
.............. Respond to CSU code
lbo ................ Set DS1 Line Build Out
Содержание Access Bank II SNMP
Страница 17: ...xx ...
Страница 37: ...3 8 9 24 01 ...
Страница 47: ...4 10 9 24 01 ...
Страница 61: ...5 14 9 24 01 ...
Страница 69: ...6 8 9 24 01 ...
Страница 87: ...FXS ID Configuration 8 14 9 24 01 ...
Страница 97: ...Battery Reversal FXS Dial Pulse Origination Card 9 24 9 24 01 ...
Страница 103: ...12 Channel FXO Dial Pulse Termination Card 10 6 9 24 01 ...
Страница 121: ...4 Wire E M TO Configuration 11 18 9 24 01 ...
Страница 139: ...12 18 9 24 01 ...
Страница 144: ...Replacing the Controller Card 9 24 01 13 5 Figure 13 3 Replacing the Controller Card ...
Страница 145: ...13 6 9 24 01 ...