LED Test and Status Indicators
9/24/01
12-13
SNMP Control Panel. Setting this switch to the Alarm Cut-Off position (ON) opens the alarm relay
contacts (150 Vrms, 150 mA maximum load) that close when the Access Bank II - SNMP enters an
alarm state.
Table 9-3 defines the pin functions on the 50-pin Tip & Ring jack.
Table 12-3: 50-Pin Tip & Ring Jack
12.11 LED Test and Status Indicators
Five test and status LED indicators on the Access Bank II - SNMP Control Panel provide a visual
means of identifying system, T1 line and V.35 interface troubles.
Table 12-4: T1 Line Status LEDs for T1 Span 1 and T1Span 2
Pin Location
Function
26
1
Tip Channel 1
Ring Channel 1
27
2
Tip Channel 2
Ring Channel 2
↓
↓
49
24
Tip Channel 24
Ring Channel 24
50
25
Alarm Tip Channel 25
Alarm Ring Channel 25
State
Meaning
OFF
Loss of T1 signal, no pulses received.
GREEN
Access Bank II - SNMP is in frame
with a frame-bit error rate <10E-5.
FLASHING GREEN
Access Bank II - SNMP is in frame,
but frame-bit error rate exceeds 10E-
5.
RED
AIS (Unframed All Ones Signal)
received from the incoming T1 span.
FLASHING RED
Access Bank II - SNMP is not syn-
chronized to the incoming T1 line,
but no AIS is being received.
YELLOW
BPV errors received on the T1 line
that are not due to B8ZS line coding.
FLASHING YELLOW
Yellow Alarm received from the T1
line.
Содержание Access Bank II SNMP
Страница 17: ...xx ...
Страница 37: ...3 8 9 24 01 ...
Страница 47: ...4 10 9 24 01 ...
Страница 61: ...5 14 9 24 01 ...
Страница 69: ...6 8 9 24 01 ...
Страница 87: ...FXS ID Configuration 8 14 9 24 01 ...
Страница 97: ...Battery Reversal FXS Dial Pulse Origination Card 9 24 9 24 01 ...
Страница 103: ...12 Channel FXO Dial Pulse Termination Card 10 6 9 24 01 ...
Страница 121: ...4 Wire E M TO Configuration 11 18 9 24 01 ...
Страница 139: ...12 18 9 24 01 ...
Страница 144: ...Replacing the Controller Card 9 24 01 13 5 Figure 13 3 Replacing the Controller Card ...
Страница 145: ...13 6 9 24 01 ...