© 2012, Carmanah Technologies Corporation. 63966_EG_Series_UserManual_RevB
EG-SERIES USER MANUAL
EG 300 PRoGRAMMER
6
EG-Series Programmer
The programmer is used to program the EMS with
the correct operating profile for your application.
The programmer is also used to test the EG-series
system to confirm correct operation. The programmer
is powered by two AA batteries (not included), and
communicates with the EG-series EMS using two-way
infrared signals.
The programmer has two buttons: Send and Test. The
Send button is used to upload the operating profile
(parameters) to the EG-series EMS, while the Test
button is used to test that the EG-series system is
operating correctly.
The 12 knobs and switches on the programmer
come pre-configured with the correct settings for your
application. If the knobs or switches get moved acci-
dentally, return them to the positions indicated by the
faceplate label.
NOTE
The EG-series uses two-way
communication between the
programmer and EMS. Therefore
each EG-series EMS must be
programmed one at a time.
Problems arise when more than
one EMS is in range during
programming.
The programmer has indicator lights and a beeper
to convey status to the user. The following table
summarizes the meanings of the lights and the
beeper:
Feedback
Status
Three short beeps & green OK
light ~5s after pressing/holding
Send button
Programming successful
One long beep & red Error
light ~5s after pressing/holding
Send button
Programming not successful
One short beep after pressing/
holding Test button
Test command transmitted
One long beep & red Error light
immediately after pressing Test
or Send button
Replace 2 X AA batteries in
programmer