background image

DAMM 

Rev. 02/17/12

STEP 7: CLEAR ANGLE VALUE OR CALCULATING ANGLE ANAIN OR SAVE ANGLE RECORD

SETUP MENU INTRODUCTION

• 

Press     to clear the current angle.

• 

Press     to calculate the angle from the current   

 angle. 

• 

Press     to record the current angle, and that will  

  also clear the current value displayed on the  

 

 screen. 

• 

From the current target angle screen, press and   

  hold the     button to enter the setup mode. To    
  scroll through the submenus, press the     button  
 repeatedly.
1. Direction Menu Pos and Neg (CW & CCW) 
2. Recorded value menu N001 = 30.0 3.) Clear  

 

  recorded values menu.
3. The last menu is the communication menu that is  
  only used by a certified service center. 

M  

Press

Press

Press

M  

Long
Press

Direction menu

Current target
angle

Record menu

Or

Record clear-all menu

Communication menu

Содержание DAMM

Страница 1: ...s Operation 48 hrs Battery Life 2 Standby 1 year Operating Temperature 10 60 Storage Temperature 20 70 Humidity Up to 90 non condensing Drop Test 1 m Vibration Test 3 10G Environmental Test 4 Pass Ele...

Страница 2: ...RANTY Carlyle Professional Hand Tools warrants to the original purchaser that the company s digital torque wrenches are free from defects in material or workmanship during the one year warranty period...

Страница 3: ...INSTALLATION POWER ON 1 LED Indicator 2 Buzzer 3 LCD Readout 4 Pre Set Target Angle Selection Button 5 Up Button 6 Down Button 7 Start Setting Button 8 Power on Reset Button 9 Communication Port Autho...

Страница 4: ...ill display a battery symbol under the M Memory indicator Er4 If the meter does not reset successfully for a period of time will be shown Press to do zero reset again Ensure the meter is in place on t...

Страница 5: ...o adjust the direction of operation from POS to NEG CW to CCW CHANGE ANGLE DIRECTION NOTE Each of these sections should be numbered Press to toggle through the pre set target angles M1 M9 Press or to...

Страница 6: ...r then the LCD screen will begin to flash and it will hold the angle it recorded right before the pause You will need to press to clear the screen and press to resume Note 1 There are 6 LEDs to indica...

Страница 7: ...isplayed on the screen From the current target angle screen press and hold the button to enter the setup mode To scroll through the submenus press the button repeatedly 1 Direction Menu Pos and Neg CW...

Страница 8: ...record menu press or to select the data number and view it If no record exists will be shown Continuously pressing will skip the setup menu and go back to the current target angle screen To access the...

Страница 9: ...aterproof 4 If the meter gets wet wipe it with a dry towel as soon as possible The salt in seawater can be especially damaging 5 Do not use organic solvents such as alcohol or paint thinner when clean...

Страница 10: ...h The torque wrench shut down during angle mode When restarted the torque wrench was not laying horizontally Angle module communication failure Rotational speed of the torque wrench was exceeded Note...

Страница 11: ...horas Vida de bater a 2 de reserva 1 a o Temperatura de operaci n 10 60 Temperatura de almacenamiento 20 70 Humedad De hasta 90 no condensado Prueba de ca da 1 m Prueba de vibraciones 3 10G Prueba med...

Страница 12: ...al centro de servicio de garant a alistado a continuaci n Esta garant a excluye los torqu metros los cuales hayan sido sujetados al uso anormal accidentes la negligencia o la falta de mantenimiento S...

Страница 13: ...1 L mparas indicadoras DEL 2 Alarma timbre 3 Lectura de salida DCL 4 Bot n de selecci n de ngulo meta pre ajustado 5 Bot n hacia arriba 6 Bot n hacia abajo 7 Bot n de comienzo ajustes 8 Bot n de ence...

Страница 14: ...de Memoria M Er4 Si el calibrador no se reinicia exitosamente por un periodo de tiempo aparecer Presione para reiniciar a cero de nuevo Aseg rese que el calibrador est en lugar en la herramienta en re...

Страница 15: ...ra actual Finalmente se mostrar el ngulo meta actual Para ajustar el sentido de la operaci n de POSITIVO a NEGATIVO CW a CCW CAMBIE EL SENTIDO DEL NGULO NOTA Cada una de estas secciones deben ser enum...

Страница 16: ...del calibrador entonces la pantalla LCD comenzar a parpadearse y ste sostendr el ngulo el cual se grab justo antes de la pausa Ser necesario presionar para borrar la pantalla y despu s presionar para...

Страница 17: ...talla actual de ngulo presione y sostenga el bot n para entrar al modo de inicio Para desplegarse hacia arriba abajo por los submen s presione el bot n repetidamente 1 Men de sentido positivo y negati...

Страница 18: ...rchivo presione o para seleccionar el n mero del dato y verlo Si no existe ning n archivo aparecer Al presionar continuamente se saltar el men de inicio y se volver a la pantalla del ngulo meta actual...

Страница 19: ...a no es impermeable contra agua 4 Si el calibrador se llegara a mojar l mpielo con un trapo seco lo antes posible La sal en el agua del mar puede ser especialmente da ino 5 No use solventes org nicos...

Страница 20: ...e apag durante el modo de ngulo Cuando se encendi de nuevo el torqu metro no estuvo colocado horizontalmente Falla de comunicaci n del m dulo de ngulo Se excedi la velocidad giratoria del torqu metro...

Отзывы: