FEATURES AND FUNCTIONS
BATTERY INSTALLATION
• Insert two AAA batteries matching the -/+ polarities of the
battery to the battery compartment.
• Fasten the screw of the battery cover.
Note:
During resetting process, do not vibrate or shake the meter.
Keep it at rest and in position. The angle meter needs to be set
on top of the tool it will be used with and set in place without any
motion to allow sensor to find home position. Wait until 4 zeros
stop blinking and target torque angle is displayed. After the target
setting is displayed, the meter then can be adjusted using the up
and down arrow keys.
BATTERY INSTALLATION
POWER ON
1. LED Indicator
2. Buzzer
3. LCD Readout
4. Pre-Set Target Angle Selection Button
5. Up Button
6. Down Button
7. Start/Setting Button
8. Power on/Reset Button
9. Communication Port
(Authorized service center use only)
10. Battery Compartment
11. Magnet
1
2
3
7
8
9
10
6
5
4
Press
Current target torque
M
Note:
The direction sign
or
will
show .Then the LCD shows
. It indicates the
meter is under resetting process. If the reset process is
completed, the target angle will be shown.
For example is shown.
• Gently press to power on.
REPLACEMENT PARTS AVAILABLE AS:
RSDAMMBC
Battery Cap
RSDAMMCS
Blow Mold Case
for DAMM
No other internal parts are available due to the
sensitivity of this professional model.
Please utilize the repair facility listed under the
warranty statement for all repairs in and out of
warranty.