38
WM5-96 Instruction Manual
Layout and list of modules
Model
WM5-96 with optical port
ANSI C12.18 type
WM5-96 without optical port
AD2001
AD2000
WM5 96
WM5 96
(Range code + system) measuring inputs
400/690VL-L 1/5A (10A)
120/208VL-L 1/5A (10A)
AQ2030
AQ2031
AV5.3
AV6.3
Power supply
18-60VAC/DC Power supply
90-260VAC/DC Power supply
AP1021
AP1020
L
H
None
Ethernet/Internet port
Digital inputs
Digital aux
Open collector output
Open collector output
Open collector output
Relay output
Analogue output 20mADC
Analogue output 10VDC
Analogue /-5mA
1
3
3
4
2
1
1
2
2
2
AR1061
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO2050
AO2051
AO2052
XX
E2
D1
D2
O4
O2
O1
R1
B1
W1
B2
None
Digital inputs
Digital aux
Open collector output
Open collector output
Open collector output
Relay output
Analogue output 20mADC
Analogue output 10VDC
Analogue /-5mA
RS485 9600bps
RS485 115200bps
3
3
4
2
1
1
2
2
2
1
1
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO2050
AO2051
AO2052
AR1034
AR2040
XX
D1
D2
O4
O2
O1
R1
B1
W1
B2
S1
S2
None
Digital inputs
Digital aux
Open collector output
Open collector output
Open collector output
Relay output
Relay output
Analogue output 10VDC
Analogue /-5mA
3
3
4
2
1
1
2
2
2
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO1035
AO2051
AO2052
XX
D1
D2
O4
O2
O1
R1
R2
W1
B2
None
Digital inputs
Digital aux
Open collector output
Open collector output
Open collector output
Relay output
Relay output
Analogue output 10VDC
Analogue /-5mA
3
3
4
2
1
1
2
2
2
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO1035
AO2051
AO2052
XX
D1
D2
O4
O2
O1
R1
R2
W1
B2
Description
Ch
Part No.
Legend
WM5 96 AV53 H XX XX XX XX XX
Material
Code
WM5 96
AV53 measuring inputs (400/690VL-L)
90-260VAC/DC power supply
20mA analogue output (2 channels)
RS485 serial port at 9600 bps
Relay output (2 channels)
Open collector output (2 channels)
RS232 serial port +RTC
AD2001
AQ2030
AP1020
AO2050
AR1034
AO1035
AO1036
AR1039
Examples of which modules to order for:
WM5-96 AV53 H B1 S1 R2 O2 SX
B
S
L
O
T
A
S
L
O
T
C
S
L
O
T
D
S
L
O
T
Utility grade with optical port
RS232 + RTC (utility grade)
Revenue approval. An “instru-
ment setting” form must be prop-
erly filled in by the user.
RS232+RTC + “XU” option
RS232 + RTC (utility grade) with-
out optical port.
1
1
1
AR1039
AR1039
AR1039
XX
SX
XU
SU
YY
SY
O
P
T
I
O
N
S
A
B
C
D
E
Measuring
input
(range+
system)
Power supply
E
S
L
O
T
Содержание WM5-96 - PROGRAMMING
Страница 1: ...WM5 96 Smart Power Quality Analyzer Instruction manual...
Страница 2: ......
Страница 12: ......
Страница 54: ......