18
Programming WM5 96
DEFAULT TARIFF
(14)
: it is the tariff (from 1 to 12) which will be cou-
pled to the meters if no other programming is made or for the days
(periods) set as non-working. Select DEFAULT TARIFF with the “
” keys and confirm with the “S” key. Then set by means of the “
” keys the tariff
(15)
that will be set as DEFAULT TARIFF, and confirm
with “S”.
ENERGY RESET
(16)
: reset the ENERGY METERS choosing among:
TOTAL, PARTIAL: resets all energy meters, both total and partial.
TOTAL +: resets the total meters of imported energy.
TOTAL -: resets the total meters of exported energy.
P: resets the partial meters of imported energy.
PARTIAL -: resets the partial meters of exported energy. To reset the
meters, select ENERGY RESET from the METERS MENU
(16)
by
means of the “
” keys and confirm with “S”; then select the type
of RESET to be carried out by means of the “
” keys and confirm
with “S”. Before carrying out the selected reset, the instrument displays
the following message: PAY ATTENTION, THE SELECTED METERS
WILL BE RESET! WILL YOU CONTINUE?: choose YES to proceed with
the reset or NO to cancel it.
TOTALIZER RESET
(18)
: reset the TOTALIZERS choosing among:
ALL TOTALIZER
(19)
: reset all the totalizers.
The other strings identify the totalizers set before that you want to
reset individually (GAS, HOT H2O, COLD H2O, REMOTE HEATING).
To reset the totalizers, select TOTALIZER RESET from the METERS
MENU
(20)
by means of the “
” keys and confirm with “S”; then
select the type of RESET to be carried out by means of the “
”
keys and confirm with “S”. Before carrying out the selected reset, the
instrument displays the following message: PAY ATTENTION, THE
SELECTED TOTALIZERS WILL BE RESET! WILL YOU CONTINUE?:
choose YES to proceed with the reset or NO to cancel it.
WM5-96 Instruction Manual
TTIIMMEE PPEERRIIOODD SSEELLEECCTTIIOONN
WEEK TYPE
PERIODS
DEFAULT TARIFF
> 2s
Go back
14
TTIIMMEE PPEERRIIOODD SSEELLEECCTTIIOONN
WEEK TYPE
PERIODS
DEFAULT TARIFF
> 2s
Go back
15
TARIFF ?
1
16
> 2s
Go back
********RREESSEETT MMEETTEERRSS********
TOTAL, PARTIAL
TOTAL
+
TOTAL
-
PARTIAL
+
PARTIAL
-
17
> 2s
Go back
Confirm
123...
Confirm
18
19
20
> 2s
> 2s
Measure
> 2s
Go back
Go back
Confirm
**********MMEETTEERRSS MMEENNUU**********
TARIFF
ENERGY RESET
TOTALIZER RESET
**********MMEETTEERRSS MMEENNUU**********
TARIFF
ENERGY RESET
TOTALIZER RESET
******RREESSEETT TTOOTTAALLIIZZEERR******
ALL TOTALIZER
(C1) REMOTE
(C2) REMOTE
(C3) GAS
******RREESSEETT TTOOTTAALLIIZZEERR******
ALL TOTALIZER
(C1) REMOTE
(C2) REMOTE
(C3) GAS
PPAAYY AATTTTEENNTTIIOONN,, TTHHEE
SSEELLEECCTTEEDD TTOOTTAALLIIZZEERRSS
WWIILLLL BBEE RREESSEETT!!
WWIILLLL YYOOUU CCOONNTTIINNUUEE??
NNOO
YYEESS
Содержание WM5-96 - PROGRAMMING
Страница 1: ...WM5 96 Smart Power Quality Analyzer Instruction manual...
Страница 2: ......
Страница 12: ......
Страница 54: ......