4.
Then click on the ‘Change’ button to set
up the connections and the data size. The data size is configured
in number of devices with corresponds to the number of RG..N solid state relays connected to the NRGC-
EIP. In the below example 32 Devices (RG..Ns) are selected for each of the two connections (Exclusive
Owner and Input Only).
5.
Select the ‘Disable Keying’ from the
Electronic Keying
drop down and then click
‘
OK
’
.
6.
Click
‘Y
es
’
when the following message window pops-up.
7.
Click on the
Connection
tab and set the Request Packet Interval for each connection. Note that they
acceptable range of the RPI is between 8ms and 1000ms.
8.
Finally configure the device type and the corresponding start-up parameters for each end-device from
the Configuration tab. For more information on the start-up parameters see section 4.3.