Planning and design
16
You should mount the three cabinets
C1, C2
and
C3
as shown in the scheme above. If it is not
possible, you should find an alternative placement.
Note: the distance between the cabinet and the last sensor on a line has not to exceed a
voltage drop of 3.5 V.
1. C1 should contain power supplies for Lanes 1, 2:
•
Power supplies for Displays A and B
•
Dupline® Master Generator SBP2MCG324 for Lanes 1 and 2
•
The UWP 3.0 controller and/or the SBP2CPY24 Server (if more than one UWP 3.0
contoller is used)
2. C2 should contain modules for lanes 3 and 6
3. C3 should contain modules for lanes 4 and 5
4. Additional floors would be managed in the same way
5. The cabinets have to be placed closed to the B, C and D displays, providing us with the
shortest practical distance between the lanes.