Car Park 3
–
Planning and design
18
The two displays showing the available bays on all the disabled parking bays are connected to any
3-wire Dupline® bus via a display interface module.
In this example, we have 12 lanes so we need 12 SBP2MCG324s, one for each lane.
Note: It is possible to manage the system with fewer SBP2MCG324s, but to keep the installation
easy and logical, we use one SBP2MCG324 for each lane.
Having 12 SBP2MCG324s, we need two UWP 3.0 controllers and one SBP2CPY24 server
.
Every SBP2MCG324 has a unique SIN number and it is connected to its local Car Park controller
(UWP 3.0).
Afterwards, the two UWP 3.0s are connected to the CPY Server (SBP2CPY24)
to send the data to
the UWP 3.0 controllers.
The best installations have a well-thought-out layout as too many displays may become
counterproductive due to information overload.
On the level 2, we could have a display at the entrance that shows only the available bays of this
level.
Note: The disabled parking bays are not included.
A simple display (L31) showing a green arrow or a red cross is placed at the entrance of the level
2.
On each lane, we place a simple display with an arrow/a red cross to show available bays in that
direction.