NOTE
OPERATION
SETPOINT VOLTAGE
The Vector spray applicator system has three voltage set-
points 1, 2, and 3. Each of these voltages can be individually
adjusted between 20 and full kV using the + and - buttons
on the front of the control unit. When the applicator trigger
is off, the present setpoint can be changed either from the
control unit or from the switch on the back of the applicator.
Setpoints cannot be adjusted below 20 kV.
Figure 5: Front View of Control Unit
POWERING UP
CONTROL UNIT
When the AC power is turned on, the unit will display the PC
board applicator type number on the kV setpoint display and
the software revision level in the µA display for 2-3 seconds.
Figure 4: Control Unit Start-Up Display
Description
Applicator Type
1
5
85 kV Cascade
65 kV Cascade
Setting and Changing the Setpoint
at the Control Unit
From the factory, Preset 1 is full minus 20 kV, Preset 2 is
full kV minus 10, and Preset 3 is full kV. For 79500/79523
full kV is 85 kV. For 79501 full kV is 65 kV.
At the control unit with the applicator not triggered, press
the 1, 2, or 3 button on the front panel of the control unit.
(See Figure 5 for positions of the kV setpoint and adjust
buttons.) The only place to adjust the kV of each setpoint
is at the control unit.
START-UP DISPLAY
CAUTION
!
DO NOT
connect a 65 kV applicator to a unit setup
for 85 kV. Damage to 65 kV barrel assembly may occur.
AH-06-01-R17 (08/2019)
30 / 79
www.carlisleft.com