![Carlin EZ-1 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/carlin/ez-1/ez-1_manual-supplement_2558416002.webp)
Instruction manual
™
Contents
PLEASE read this first.......................................................... 2
Codes and standards........................................................... 2
EZ-1/2/3 application information ....................................... 3
Prepare site • assemble burner • mount burner ............. 5
Prepare burner ................................................................... 10
Wire burner • start burner — 48245 primary control ... 14
Wire burner • start burner — 40200/42230 primary ..... 16
Wire burner • start burner — 50200 primary control ... 18
Wire burner • start burner — 60200 primary control ... 20
Adjustment and verification ............................................. 22
Annual start-up and service............................................. 23
Repair parts......................................................................... 24
Maintenance procedures ................................................. 26
Limited warranty ................................................................ 27
User care and maintenance ............................ Rear cover
...................................................................................................
70 Maple Street
East Longmeadow, MA 01028
Ph 413-525-7700
Fx 413-525-8306
Carlin Combustion Technology, Inc.
T
ech
support
800-989-2275
carlincombustion.com
©
Copyright 2010 — Carlin Combustion Technology, Inc.
Installer/servicer
— Except where specifically
stated otherwise, this manual must be used only by a
quali-
fied service technician
. Failure to comply with this or other
requirements in this manual could result in severe personal
injury, death or substantial property damage.
User
— Refer only to User’s Information booklet for
information regarding operation of this burner. The burner
Instruction Manual is intended only for your service techni-
cian. The burner and heat exchanger must be inspected and
started at least annually by your service technician.
Ratings
Input
:
EZ-1, EZ-1-HP .....................................0.50 to 1.65 GPH
EZ-2, EZ-2-HP .................................... 1.50 to 2.25 GPH
EZ-3, EZ-3-HP .................................... 2.00 to 2.60 GPH
Fuels
:
......................No. 1 or No. 2 heating oil (ASTM D396)
Fuel unit
:
............................................................................. Suntec
EZ-1,-2 or -3 .............................100
psig
nozzle
pressure
EZ-1,-2 or -3-HP ............ Over 100
psig
nozzle
pressure
Electrical
: Power .............................................. 120V/60
hz
/1-
phase
Motor...............................Carlin PSC, 1/6
hp
, 3450
rpm
Current ...............................................Approx. 2.5
amps
Ignition
:
..........Carlin Model 41000 electronic — 14,000
volts
Control
:
.................... U.L. Group I or II primary safety control
Agencies
: .......................................... UL Listed (US and Canada)
Содержание EZ-1
Страница 16: ...Carlin part number MNEZ123 Rev 01 12 10 15 Model EZ 1 2 3 oil burners Instruction manual...
Страница 18: ...Carlin part number MNEZ123 Rev 01 12 10 17 Model EZ 1 2 3 oil burners Instruction manual...
Страница 20: ...Carlin part number MNEZ123 Rev 01 12 10 19 Model EZ 1 2 3 oil burners Instruction manual...
Страница 22: ...Carlin part number MNEZ123 Rev 01 12 10 21 Model EZ 1 2 3 oil burners Instruction manual...