Carlin 51300S Скачать руководство пользователя страница 3

3

Reference 

Number

Description 

Part Number

Quantity

MODEL

51300S

51300AS

51300BS 51300CS

1

Burner Cover

50404ABLK

1

         Following items come assembled with Burner Cover (above)

1a

Burner Cover Reset Button

51288

1

1b

5/16-18 x 5/8" Phillips Head Screw

50008

1

1/4" Retaining Nylon Washer

50800

1

2

Burner Cover Backplate

50433B

1

3

CAP System Air Flow Switch (0.18" WC)

50806A

1

4

CAP System Air Flow Switch (0.30" WC)

50806B

1

5

CAP System Air Flow Switch (0.85" WC)

50806C

1

6

Clamp

51642

1

7

3" 90° PVC Elbow

51314

1

8

3" Air Intake Screen

51322

1

9

5/16" Plated Star Washer

31179

2

5/16-18 x 5/8" Hex Head Bolt

50604

2

10

CAP System Air Inlet

51300

1

         Following items come assembled with CAP System Air Inlet (above)

10a

24 inch Air Flow Switch Wiring Harness

51308A

1

10b

10-14 x 1/2" Phillips Head Screw

50605

2

10c

 8-16 x 3/4" Phillips Head Screw

51327

1

11

Connecting Flange

51305

1

12

CAP System Kit Instructions and  

Operating Manual

MNCAP

1

13

9/32"ID x 7/8" OD Grommet

51669

1

14

5/16" Plated Star Washer

31179

2

5/16-18 x 5/8" Hex Head Bolt

50604

2

15

.88" Split Grommet

51425A

2

16

Hole Plugs 

99715

4

17

1.62" Split 5Grommet

50844A

1

18

Burner Cover Oil Line Insert

50703

1

19

Burner Cover Backplate Filler

50433B1

1

         Following item comes assembled with Burner Cover Backplate Filler (above)

19a

1/8" Black Nylon Rivets

50851

2

20

Label – Burner Setup Chart

51316

1

   Components inside red box are contained in the polybag.

   

 

Components 14-20 indicate parts included with 50433KITS (Cover Seal Kit).

C A P   S Y S T E M   K I T   C O M P O N E N T S

Содержание 51300S

Страница 1: ...hout covers 0 50 2 00 51300AS Low Rate CAP Kit for Carlin burners with covers 0 50 1 00 51300BS Medium Rate CAP Kit for Carlin burners with covers 1 05 1 45 51300CS High Rate CAP Kit for Carlin burner...

Страница 2: ...C A P S Y S T E M K I T C O M P O N E N T S s e e p a g e 3 f o r p a r t d e s c r i p t i o n s 8 13 9 1 14 17 18 20 15 19 16 2 12 3 6 7 4 5 10 11 10a 10b 10c 1b 1a 19a COMPONENTS CONTAINED IN POLYB...

Страница 3: ...ssembled with CAP System Air Inlet above 10a 24 inch Air Flow Switch Wiring Harness 51308A 1 10b 10 14 x 1 2 Phillips Head Screw 50605 2 10c 8 16 x 3 4 Phillips Head Screw 51327 1 11 Connecting Flange...

Страница 4: ...the burner cover backplate 2 5 REMOVE AIR INLET KNOCKOUT Remove the 2 x 4 air inlet knockout that corresponds to the desired air inlet position vertical or horizontal as shown in step 8 Pressure Swit...

Страница 5: ...kplate 2 Secure the filler plate 19 below the burner air tube using the two 5 16 bolts and star washers 14 provided Install the 1 62 split grommet 17 around any BX cable wiring harness etc leaving the...

Страница 6: ...em air inlet 10 onto the 2 x 4 air inlet knockout removed in Step 5 Mounting examples below 9 Slide the connecting flange 11 onto the air inlet 10 until fit is tight Reverse flange when using galvaniz...

Страница 7: ...ng the cover 14 CHECK BURNER SETUP CAP System utilizes outside air for combustion Incoming air temperature will fluctuate by season which can significantly impact combustion Use the table below to set...

Страница 8: ...components in the Burner Seal Kit see Step 6 Make sure that the burner cover screw 1b is tight This also prevents basement air from entering the cover Check that the correct air pressure switch 3 4 5...

Отзывы: