Model 201GAS burner — Instruction manual

Carlin part number MN201GAS Rev. 03/14/11

– 20 –

Where appliance instructions differ from this manual, follow the appliance instructions.

9.  Replacement parts

Item

number

Description

Part

number

1

1a

Air tube with gas manifold & diffuser (specify overall length of air tube)
Gas manifold (specify air tube length, diffuser and firing rate)

Contact factory
Contact factory

2

Gasket, mounting flange

40287

3

Blower housing (burners with A or B diffuser)
Blower housing (burners with C diffuser)

98529

Contact factory

4

Air band (four-slot)
Air band (two-slot)

47001
98542

5

Airflow switch and mounting plate assembly

98521

6

Blower inlet sensing line

98557

7

Blower outlet sensing line

98558

8

Gas valve, VR4305M-4540

98523

9

9a

Gas line union, ¾"
Gas orifice nipple, ¾" NPT both ends x 4”                                                                  Starter hole orifice
                                                                                                                                                Drilled to size

29652

9938440XX

Contact factory

10

Blower wheel

28563

11

Motor, 1/6 HP (140-

WATT

 PSC)

98611

12

Junction box, 4" x 4", with grommet, lock washer, conduit nipple (to burner housing), and 
bracket (not shown)

Contact factory

13

Hinged cover plate for Carlin ignitor

98534

14

Ignitor, Carlin electronic Model 41800

4180002

15

Primary control, Carlin 60200FR microprocessor flame rod control

6020002FR

16

Ignitor electrode/flame rod assembly, complete (depends on air tube length)

Contact factory

17

Electrode holding base with hardware (depends on air tube length)

23135S

18

Flame rod (depends on air tube length)

Contact factory

19

Ignitor electrode (depends on air tube length)

20

Ignitor electrode/flame rod support rod (depends on air tube length)

21

Ignitor electrode/flame rod locator bracket

Not available 

separately

22

Welded flange (when supplied)

Included with 

air tube

23

Standard universal flange (supplied with burners without welded flange)

59642BLU

24

Optional forced draft flange

59444BLU

25

End cover plate (only on burners with C diffusers)

98331

Содержание 201GAS

Страница 1: ...trol Carlin Model 60200FR microprocessor control Agencies UL Listed Installer servicer Except where specifically stated otherwise this manual must be used only by a quali fied service technician In th...

Страница 2: ...liance service When servicing the burner Disconnect electrical supply to burner before attempting to service to avoid electrical shock or possible injury from moving parts Burner and appliance compone...

Страница 3: ...volts continuous duty rated 11 Primary control Carlin Model 60200FR microprocessor based inter rupted ignition flame supervisory control flame rectification 12 Flame current test jack O F F O N 20100...

Страница 4: ...ate do not vent into a masonry chimney that has one or more sides exposed to the outside Install a listed stainless steel liner to vent the flue products A defective vent system could result in severe...

Страница 5: ...construction is unusually tight see National Fuel Gas Code NFPA 54 ANSI Z223 1 or B149 1 B149 2 Installation Code for Canadian installations for definition you will need to provide air openings into t...

Страница 6: ...ional forced draft flange Failure to comply could result in severe personal injury death or substantial property damage See page 19 for required dimensions and bolt locations 1 Prepare site prepare bu...

Страница 7: ...C 4 11 14 8 10 9 Burners with welded flange have fixed usable tube length UTL Verify length is correct for the application Burners with adjustable flange Usable tube length UTL varies with air tube l...

Страница 8: ...ect redrill gas orifice when required Turn off power to the burner appliance before proceeding Close main manual gas valve in gas line to burner Then disconnect the ground joint union to allow rotatin...

Страница 9: ...ply pressure 14 inches w c Minimum supply pressure 5 inches w c Do not expose the combination gas valve to gas pressure in excess of 14 inches water column Higher pressure could dam age the valve seat...

Страница 10: ...rner requires a 120 vac 60 hz single phase power supply with at least a 10 amp fuse The current draw will be when equipped with typical motor and Carlin 41800 electronic ignitor approximately 2 The 12...

Страница 11: ...s prepurge timing then start the ignitor Approximately one second later the combination gas valve will open The manometer should show almost no pressure because the main manual gas valve is closed 5 A...

Страница 12: ...restart Releasing the button before the LED s turn off will cause the control to remain in latch up The 60200FR control will not reset from lockout or latch up if power is interrupted Power ON Open al...

Страница 13: ...k at flame through appliance observation port The flame should be a soft blue with well defined orange and yellow tips for natural gas or well defined yellow tips for propane gas If you make air or ga...

Страница 14: ...ontinue with normal operation If switch fails to operate correctly replace the switch and retest NEVER attempt to adjust the air pressure switch setting This could allow unsafe operation of the burner...

Страница 15: ...urner from appliance and inspect diffuser plate ignitor electrode and flame rod see Figures 5 and 6 page 8 Remove ignitor electrode flame rod assembly to clean and adjust if necessary To remove assemb...

Страница 16: ...aced remove the two bolts securing the motor to housing 2 Disconnect the motor wires in the burner junction box 3 Loosen the Allen screw securing the blower to the motor shaft and remove the wheel 4 W...

Страница 17: ...Model 201GAS burner Instruction manual Carlin part number MN201GAS Rev 03 14 11 17 Where appliance instructions differ from this manual follow the appliance instructions 7 Troubleshooting...

Страница 18: ...on of ignitor electrode per Figures 5 and 6 page 8 Adjust if needed Check primary voltage to ignitor If ignitor receives 120 VAC and doesn t generate spark replace ignitor Airflow Check air band setti...

Страница 19: ...mbers with negative overfire pres sure For pressurized firing you must obtain a burner with a welded flange designed for use with the appliance You can also use the optional Forced draft flange Failur...

Страница 20: ...e 29652 9938440XX Contact factory 10 Blower wheel 28563 11 Motor 1 6 HP 140 WATT PSC 98611 12 Junction box 4 x 4 with grommet lock washer conduit nipple to burner housing and bracket not shown Contact...

Страница 21: ...ffer from this manual follow the appliance instructions 9 Replacement parts continued Burner is shown with welded flange supplied only on burners ordered for specific appliance applications Other burn...

Страница 22: ...Model 201GAS burner Instruction manual Carlin part number MN201GAS Rev 03 14 11 22 Where appliance instructions differ from this manual follow the appliance instructions...

Страница 23: ...Model 201GAS burner Instruction manual Carlin part number MN201GAS Rev 03 14 11 23 Where appliance instructions differ from this manual follow the appliance instructions...

Страница 24: ...Model 201GAS burner Instruction manual Carlin part number MN201GAS Rev 03 14 11 24 Where appliance instructions differ from this manual follow the appliance instructions...

Отзывы: