DPM IV
Mechanics (Replace Components)
05.19
Service Instructions
59
1. Place the new pressure sensor (H) onto the connector block (I)
and tighten it with the two screws (E).
2. Place the connector block (I) with the pressure sensor (H).
3. Tighten the two screws (J).
4. Press the pneumatic tube (F) onto the push-in fitting (G).
5. Plug the plug-in connector (C) of the pressure sensor (H) onto the
motor board (D).
6. Tighten the cover plate (B) with the four screws (A).
7. Close the dust cover or fasten it with the four screws at the
hinges.
8. Fasten the top cover with the six countersunk screws.
Installing the
pressure sensor
Содержание DPM IV