Electronics (Replace Components)
DPM IV
18
Service Instructions
05.19
4.2 Input/Output Board
NOTICE!
The inputs/outputs can be tested in the
Service Functions
.
In case of an active input, the position corresponding to this input
changes to 1.
To activate an output, move the cursor to the corresponding position
and set value 1. To deactivate the output, set the corresponding
position again to 0.
Inputs and outputs marked with 'x' are not occupied.
B
C
A A
Figure 7
1. Unplug the control unit from electrical outlet.
2. Unscrew the four screws on the rear and remove the front plate
3. Unscrew the retaining screws (A) at the SUB-D socket.
4. Remove the I/O plate (B) and disconnect the plug-in connector
(C).
1. Connect the new I/O board (B) with the appropriate cable (C) and
place it.
2. Fasten the retaining screws (A).
3. Reinstall the front plate.
4. Connect the power supply cable.
Removing the
input/output board
Installing the
input/output board
Содержание DPM IV
Страница 1: ......
Страница 16: ......
Страница 26: ...Electronics Replace Components DPM IV 26 Service Instructions 05 19 ...
Страница 60: ...Mechanics Replace Components DPM IV 60 Service Instructions 05 19 ...
Страница 64: ...Cleaning DPM IV 64 Service Instructions 05 19 ...
Страница 83: ...DPM IV Wiring Plans 05 19 Service Instructions 83 9 Wiring Plans 9 1 Control Unit Figure 45 ...
Страница 84: ...Wiring Plans DPM IV 84 Service Instructions 05 19 9 2 Print Mechanics Left Version Figure 46 ...
Страница 85: ...DPM IV Wiring Plans 05 19 Service Instructions 85 9 3 Print Mechanics Right Version Figure 47 ...
Страница 86: ...Wiring Plans DPM IV 86 Service Instructions 05 19 ...
Страница 90: ...Pin Assignment of Control Unit DPM IV 90 Service Instructions 05 19 ...
Страница 95: ......
Страница 96: ......