11
Vedpak 132_501186_Version 4_12.2017
211097
Navigation
Mode#
Display
Mode/Function
Output
When the HC-CARGO
211097 is initially con-
nected to the vehicles
battery or a 12-24 volt
power supply, it enters
Mode#1
automatically.
To enter into Mode#2
press and hold Mode
button until you hear a
low pitched beep.
To enter into Mode#3
press and hold Mode
button until you hear a
high pitched beep.
To enter into Mode#4
press and hold Mode
button until you hear a
low to high pitched beep.
To enter into Mode#5
press and hold Mode
button until you hear a
mid pitched beep.
To return to Mode#1
press and hold Mode
button until you hear a
high and low beep.
#1
#2
#3
#4
#5
Power Probe Mode:
With Audio Tone On.
Power Probe Mode:
With Audio Tone Off.
Power Probe Mode:
With the Circuit
Breaker tripped with
Audio Tone On.
Power Probe Mode:
with the Circuit
Breaker tripped with
Audio Tone Off
Negative Peak to
Peak Mode
Positive Peak to
Peak Mode
Peak to Peak Mode
Peak to Peak
Threshold Setting
Mode: Detects Peak
to Peak in Power
Probe Mode.
Displays the average
D.C. voltage.
Displays the Peak
to Peak A.C. voltage
when the voltage is
more than
Mode 5
Threshold
setting.
Limited to 65 V.
Captures the most
negative
voltage
transition.
Captures the most
Positive
voltage
transition.
Displays the
difference between
Peak to Peak
voltage.
Sets the
Peak to
Peak Threshold
Level
for the
Mode#1 display to
transition from D.C.
to A.C.
Actively alterna-
ting + to ÷ to +,
etc.