background image

Set wireless remote control (CF RX TX)  

3 functions

 

Cargofloor.com   

Page 5

 

Version 01 / 05-07-2021

 

Y) 

It is at all times advisable to stop the Cargo Floor system when all the piston rods are retracted. 
This is usually the case when the floor profiles are positioned towards the unloading end (vehicle 
doors). Unretracted piston rods may cause damage to the Cargo Floor system. 

Z) 

To prevent damage to the floor profiles, exercise caution and limit the dump height as much as 
possible. The transport of unauthorised goods, such as aggressive, corrosive, hot, hard, sharp and 
viscous materials may cause damage to the Cargo Floor system and the vehicle. Avoid loading 
and unloading sharp objects. Loads that are softer than the hardness of the floor profiles will 
extend the service life of your system; if in doubt, use a protective cloth or consult your dealer. 

AA)  Forklift trafficable. In principle, the floors are completely trafficable and can be driven over by 

forklifts, but always consult your dealer for advice on the maximum loads allowed on your vehicle. 
Overloading will cause damage to the Cargo Floor system and the vehicle. 

BB)  Always return emergency control(s) to their original non-activated position after use. 
CC)  During the operation of the system, test the temperature of the oil by touching the side of the tank. 

If the oil is so hot that you cannot continue to touch the tank, switch off the pump to allow the oil to 
cool off and determine what is causing the overheating. Stop loading or unloading if the oil is too 
hot, as this will irreversibly cause damage to the Cargo Floor system and the other hydraulic 
components. 
WARNING:  TOUCHING OVERHEATED OIL AND COMPONENTS CAN CAUSE BURNS AND 
INJURIES! 
Option: your Cargo Floor system could be equipped with an oil temperature safety switch which will 
switch off the system automatically when it starts to overheat.  

DD)  During loading and unloading operations, the load should be spread to give an even weight 

distribution over the floor area, otherwise the load may stall. Tip: when transporting pallets, place 
softwood boards of  300 x 18 x 2350 mm. [12” x 0.75” x 92.5”] to distribute the pressure more 
evenly. 

EE)  The constant pressing of the load against the head board or the doors can lead to extra wear of 

the complete system. Also the construction can be damaged. Please consult your supplier about 
the optimizing possibilities or in order to prevent problems occurring.  

FF)  The user/operator/driver that is operating the Cargo Floor system is compelled to remain a safe 

distance from the Cargo Floor system at all times, from the time of switching on the hydraulic pump 
until turning it off. He should ensure that no dangerous situations can occur. When the process 
malfunctions or if other people are present he should shut down the Cargo Floor system, or 
hydraulic pump, immediately.  

GG)  No unauthorized alterations/modifications/changes/adjustments may be made to any part of the 

Cargo Floor drive unit and system. 

 

WARRANTY 

Warranty is subject to prior approval by Cargo Floor B.V.! To request warranty coverage, visit 
Cargofloor.com to fill out and submit the warranty application form provided there; do not forget to 
include your Cargo Floor system number on the form. 
 
 

EMERGENCY STOP 

 
In the event of an EMERGENCY, operation of the Cargo Floor system can be halted as follows: 

 

By pressing the red stop button on one of the control switches; 

 

By turning all 

switches to position “0”; 

 

By putting the handle of the control valve in the middle “0” position (only B and A control); 

 

Turning off the PTO pump/engine; 

 

Turning off the main switch of the power supply; 

 

Turning off the motor of the electro-hydraulic aggregate. 

 

Содержание 6104006

Страница 1: ...com Page 1 Version 01 05 07 2021 CARGO FLOOR INSTALLATION MANUAL WIRELESS REMOTE CONTROL CARGO FLOOR CF RX TX 3 FUNCTIONS PARTS NO 6104006 Cargo Floor B V World s leading manufacturer and supplier of...

Страница 2: ...If the Cargo Floor remote control does not or not correctly function after following the operating instructions please contact your supplier who will undoubtedly assist you in eliminating the fault Al...

Страница 3: ...MES product could fall on top of you Both could result in damages and or injuries It is always advisable to use the pneumatic door lock if provided B 1 Check that the vehicle s quick detachable coupli...

Страница 4: ...go Floor system and the hydraulic pump must be shut down immediately Subsequently check all the checkpoints before switching the pump and the Cargo Floor system back on To prevent the oil from overhea...

Страница 5: ...system could be equipped with an oil temperature safety switch which will switch off the system automatically when it starts to overheat DD During loading and unloading operations the load should be s...

Страница 6: ...ol replaces the CF4 wired remote control CHECK BEFOREHAND BE CAREFUL When the pump PTO is switched on the system can start moving immediately With certain versions the functions can deviate from the s...

Страница 7: ...es in the corners of the mounting plate must be on the underside Mount the receiver with the 4 M4x15 bolts and locknuts on the mounting plate with the gland cable entry of the receiver at the bottom T...

Страница 8: ...Button 3 stop Stops the system B control The remote control for B controlled Cargo Floor systems If you have a Cargo Floor system with B control you can remove the E sticker from the control and repla...

Страница 9: ...and play If a new or second remote control has to be used in combination with the receiver you can connect them as follows Press the Function programming button once Press the Select programming butt...

Страница 10: ...as possible towards the outside of the trailer Because of possible reception problems we strongly advise against installing the receiver in a steel box Prevent damages to the receiver Therefore do no...

Страница 11: ...com Order spare parts E mail address sales2 cargofloor com DID number 31 524 593 922 After Sales technical questions and malfunctions E mail address as cargofloor com DID number 31 524 593 981 31 524...

Отзывы: