CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 22 -
# port#4.
ceschclkset 1 2
ceschclkset 2 2
ceschclkset 3 2
ceschclkset 4 2
#Enable E1 port#1 to port#4, and specifically set the destination
#IP and MAC address of the remote device (CPE).
ceschset 1 1 172.16.1.2 00:0b:f9:10:01:02
ceschset 2 1 172.16.1.2 00:0b:f9:10:01:02
ceschset 3 1 172.16.1.2 00:0b:f9:10:01:02
ceschset 4 1 172.16.1.2 00:0b:f9:10:01:02
lanset 1 7
csave
Script for setting
CPE
site configuration back to default IV
gci
srcnet 172.16.1.2 255.255.255.0
ipset 192.168.2.11 255.255.255.0 172.16.1.1
cespwidset 1 1 1
cespwidset 2 2 2
cespwidset 3 3 3
cespwidset 4 4 4
pktsize 1 1
pktsize 2 1
pktsize 3 1
pktsize 4 1
jitterbd 1 1
jitterbd 2 1
jitterbd 3 1
jitterbd 4 1
ceschclkset 1 0
ceschclkset 2 0
ceschclkset 3 0
ceschclkset 4 0
ceschset 1 1 172.16.1.1 00:0b:f9:10:01:01
ceschset 2 1 172.16.1.1 00:0b:f9:10:01:01
ceschset 3 1 172.16.1.1 00:0b:f9:10:01:01
www.carelink.com