CL-MC-XE1-IP-Y Series (1/2/4 E1) User Manual
- 20 -
#Set both transmitting and receiving pseudowire ID to 2 for E1 port#2
cespwidset 1 1 1
cespwidset 2 2 2
#Set the transmit packet size to 782 byte for both E1 port#1 and
# port#2.
pktsize 1 1
pktsize 2 1
#Set the jitter buffer depth to 11.5msec for both E1 port#1 and
# port#2.
jitterbd 1 1
jitterbd 2 1
#Set the transmit clock source to RxLine for both E1 port#1 and
# port#2.
ceschclkset 1 2
ceschclkset 2 2
#Enable both E1 port#1 and port#2, and specifically set the
#destination IP and MAC address of the remote device (CPE).
ceschset 1 1 172.16.1.2 00:0b:f9:10:01:02
ceschset 2 1 172.16.1.2 00:0b:f9:10:01:02
lanset 1 7
csave
Script for setting
CPE
site configuration back to default III
gci
srcnet 172.16.1.2 255.255.255.0
ipset 192.168.2.11 255.255.255.0 172.16.1.1
cespwidset 1 1 1
cespwidset 2 2 2
pktsize 1 1
pktsize 2 1
jitterbd 1 1
jitterbd 2 1
ceschclkset 1 0
ceschclkset 2 0
www.carelink.com