OTHER SPECIFICATIONS
storage conditions
-40T70 °C, 90% rH non-condensing
operating conditions
-25T60 °C, 90% rH non-condensing
index of protection
IP20, IP40 front panel only on the versions without ultracap module
environmental pollution
2
class according to protection against electric shock
to be integrated into Class 1 and/or 2 appliances in the versions
without valve driver, Class 1 in versions with valve driver.
PTI of the insulating materials
PCB: PTI250; insulation material: PTI 175
period of stress across the insulating parts
long
type of action
1C; 1Y for SSR versions
type of disconnection or microswitching
microswitching
category of resistance to heat and fi re
category D (UL94 - V2)
immunity against voltage surges
overvoltage category: II for all I/Os except for the high voltage digi-
tal outputs and digital inputs (class II circuits), which are category I
ageing characteristics (operating hours)
80,000
no. of automatic operating cycles
100,000 (EN 60730-1); 30,000 (UL 873)
software class and structure
Class A
category of immunity to voltage surges (IEC EN 61000-4-5)
Category 3
The device is not designed to be hand-held when powered.
P
roduct certifi cations
Electrical safety
EN 60730-1, EN 60730-2, UL60730
Electromagnetic compatibility Versions without valve driver: EN 61000-6-1, EN 61000-6-2, EN 61000-6-2/EC, EN 61000-6-2/IS1,
EN 61000-6-3, EN 61000-6-4; EN 55014-1, EN 55014-2, EN 55014-2/EC, EN 55014-2/A1,
EN 55014-2/IS1, EN 55014-2/A2
Versions with valve driver, with or without ultracap module: EN 61000-6-1, EN 61000-6-2, EN
61000-6-2/EC, EN 61000-6-2/IS1, EN61000-6-3, EN 61000-6-4
WARNINGS
• for applications subject to considerable vibrations (1.5 mm pk-pk 10/55 Hz), secure the cables connected to the pCO
5
around 3
cm from the connectors using clamps;
• cables longer then 10 m, excepted the cables for relays and 230 Vac digital inputs, must be shielded with shield connected to
the ground;
• in residential environments (EN55014), in the versions without valve driver the connection cable between the pCO
5
, the
terminal and the other serial boards must be shielded and earthed at both ends;
• the device must be installed according to the standards and legislation in force in the country where it is used;
• for safety reasons the equipment must be housed inside an electrical panel, so that the only accessible part is the display and
the keypad;
• all the extra low voltage connections (analogue and 24 Vac/Vdc digital inputs, analogue outputs, serial bus connections, power
supplies) must have reinforced or double insulation from the mains network;
• in the event of malfunctions, do not attempt to repair the device, but rather contact the CAREL service centre;
• make sure that the temperature inside the panel where the pCO
5
is installed does not exceed the operating conditions
ACCESSORIES
PCOS00AKY0
pCO Sistema smart key
0907877AXX
external ferrite for pCO
5
power cable
S90CONN002
pGD terminal connection cable L= 0.8 m
S90CONN000
pGD terminal connection cable L= 1.5 m
S90CONN001
pGD terminal connection cable L= 3 m