25
“UE BASIC” +08C0042EZ - rel. 1.0 - 16.10.2017
ENG
Table of water circuit, electrical and electronic spare parts, UE025 to UE065
description
spare part code
pos. figure
UE025
UE035
UE045
UE065
Water circuit
Drain pump hose
UEKDH00000
7
9.c
Manifold UEKCOLL000
6
9.c
Drain pump kit
KITPSE0000
5
9.c
Internal tubing kit
UEKT10000L
UEKT1000XL
3
9.c
Double check valve kit
FWHDCV0000
-
Conductivity meter kit
KITCN00000
4
9.c
Fill solenoid valve kit
KITVC10058
KITVC10070
2
9.c
Drain circuit
UEKDC00000
UEKDC10000
1
9.c
Electrical and electronics
Display terminal
HCTLEYFCw0
(3)
18
9.d
TAM (current transformer)
UEKTAM0000
9
9.d
Contactor
UEKCONT200
URKCONT400
URKCONT300
10
Power transformer: 230/400-24V
UEKTR30000
11
9.d
Electronic controller
UEYxxvCz0i
(2)
14
9.d
Fuse carrier
URKFH20000
13
9.d
Pump control relay
UEKRD00000
-
F1 - F2 230 to 400Vac power fuses
UEKFUSE100
UEKFUSE100
UEKFUSE100
UEKFUSE100 -
see wiring diagrams
F3 Pump fuse
URKFUSE300
-
see wiring diagrams
F4 Transformer secondary fuse
UEKFUSE400
-
see wiring diagrams
Connection cable between
terminal and electronic controller
S90CONN002
-
Tab. 9.c
(1) when ordering, as well as the controller code specify the complete code and serial number of the humidifier.
(2) xx: kg/h ( 01,......65) - v: power supply ( K=230V 3ph, L=400V 3ph, etc )
z: match digit board (8th code number of the card) - i: 0 single package / 1 multiple package
(3) w: match digit terminal (9th code number of the terminal)
Table of spare parts for standard and special cylinders UE025 to UE065
Description
UE025
UE035
UE045
UE065
STANDARD openable cylinders
400V 3ph cylinder, conductivity 350 to 1250 μS/cm
BLCT4D00W2
BLCT4D00W2
BLCT4C00W2
BLCT5C00W0
SPECIAL openable cylinders
400V 3ph cylinder, conductivity 75 to 350 μS/cm
BLCT4C00W2
BLCT4C00W2
BLCT4B00W2
BLCT5B00W0
SPECIAL not openable cylinders
400V 3ph cylinder, conductivity 75 to 350 μS/cm
BL0T4C00H2
BL0T4C00H2
BL0T4B00H2
BL0T5B00H0
400V 3ph cylinder, conductivity 350 to 1250 μS/cm
BL0T4D00H2
BL0T4D00H2
BL0T4C00H2
BL0T5C00H0
Electrode and gasket kit
400V 3ph cylinder, conductivity 75 to 350 μS/cm
KITBLCT4C2
KITBLCT4C2
KITBLCT4B2
KITBLCT5B0
400V 3ph cylinder, conductivity 350 to 1250 μS/cm
KITBLCT4D2
KITBLCT4D2
KITBLCT4C2
KITBLCT5C0
Gasket and filter kit
KITBLC4FG0
KITBLC4FG0
KITBLC4FG0
KITBLC5FG0
Tab. 9.d
9.3 Cleaning and maintenance of the cylinder
Replacement
Important:
he cylinder must be only be replaced by qualified personnel, and with
the humidifier unplugged from the power supply.
In normal conditions, the
disposable cylinders should be replaced after one year
(or
2500 hours of operation, if cleaned periodically), while the
openable cylinders last 5 years
(or 10,000 hours of operation, if cleaned periodically). They must be replaced immediately
– even before the specified intervals – if any anomalies occur. For example, when the lime
scale inside the cylinder prevents the correct flow of electric current.
Replacement procedure:
1.
empty all the water (see chap. 6);
2.
turn off the humidifier (switch “0”), and open the mains disconnect switch on the
power supply (safety procedure);
3.
wait for the humidifier and the cylinder to cool down;
4.
remove the front cover;
5.
disconnect the electrical cables from the cylinder;
6.
release the cylinder from the locking device and lift it to remove it;
7.
insert the new cylinder (make sure that the model and the power supply of the new
cylinder correspond to the rated data);
8.
fasten the cylinder;
9.
reconnect the electrical cables to the cylinder;
10.
replace the front cover;
11.
switch on the humidifier;
12.
reset cylinder operating hour counter (see parameters da , chap. 7);
13.
Activate the wash new cylinder procedure, pressing ENTER + DOWN for 5 seconds
Periodical checks
•
After one hour
of operation: check for any significant water leaks.
•
Every 15 days
or no more than 300 operating hours: check operation, the absence of
significant water leaks, the general conditions of the casing. Check that during operation
there are no arcs or sparks between the electrodes.
•
Every 3 months
or no more than 1000 operating hours:
Содержание humiSteam UE005
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 27: ...27 UE BASIC 08C0042EZ rel 1 0 16 10 2017 CN 10 䐥ഴ 10 1 㧞㼁UE005 UE015ㅴ㼀㵝 Fig 10 a 䐹䄋 䇻TAM㞅䐤 㑍ㅴ 㤌 㾂ㅻ11 1 ...
Страница 28: ...28 UE BASIC 08C0042EZ rel 1 0 16 10 2017 CN 10 2 㧞㼁UE025 UE065ㅴ㼀㵝 Fig 10 b 䐹䄋 䇻TAM㞅䐤 㑍ㅴ 㤌 㾂ㅻ11 1 ...
Страница 42: ......
Страница 44: ......
Страница 79: ......