Humidisk - user manual

Rel. 1.2 del 18/03/99

2

2 Codes

2.1 Centrifugal 

Humidifier

Description

Code

HumiDisk

HDU05RM230

2.2 Electrical 

panels

Description

Code

Electrical panel for one HumiDisk

HDE05MP230

Electrical panel for two HumiDisks

HDE10MP230

2.3 

Humidistat mounted in the HDE electric panel

Description

Code

IRDRW4: 2 x relays, Din rail mounting, 24, 230 Vac, buzzer, pre-set for serial connection
and remote-control

IRDRW4000

2.4 Accessories

Description

Code

Remote control

IRTRRU(*)000

IRDRSER: serial connection board

IRDRSER000

(*) I = Italian; E = English; D = German; F = French; S = Spanish.

2.5 Humidity 

Probes

WALL probes “ASW”
Outputs

Range

Code

Humidity

10÷90%rH

ASWH10000

DUCT probes  “ASD”
Outputs

Range

Code

Humidity

10÷90%rH

ASDH100000

Humidity

0÷100%rH

ASDH200000

Содержание HDU05RM230

Страница 1: ...XPL LVN 0DQXDOH G XVR 8VHU JXLGH...

Страница 2: ......

Страница 3: ...e electrical power 8 3 5 3 Connecting the humidity probe ASH1 ASH2 ASDC11 ASDC111 ASPC11 ASPC23 ASWH1 ASWC11 ASWC111 9 3 5 4 Alarm output 9 3 5 5 Remote ON Off 9 3 6 Control panel HDE10MP230 for the c...

Страница 4: ......

Страница 5: ...for wall or hanging mounting terminal block support 1 1 Applications HumiDisk is especially suitable for applications such as cold rooms and storage facilities for fresh produce where lack of humidity...

Страница 6: ...HDE electric panel Description Code IRDRW4 2 x relays Din rail mounting 24 230 Vac buzzer pre set for serial connection and remote control IRDRW4000 2 4 Accessories Description Code Remote control IR...

Страница 7: ...ceiling must be 1000mm the minimum horizontal distance from the wall must be 114mm Unit s weight is 20Kg fully loaded The machine has to be installed in horizontal position Important do not use hemp r...

Страница 8: ...Humidisk user manual Rel 1 2 del 18 03 99 4 Hanging mounting Fig 1 Wall mounting Fig 2...

Страница 9: ...air leaving the appliance must not strike any obstacle Turn the fairing D horizontally so that the flow comes out in the desired direction Fit the SAFETY fixing brackets 2 as shown in Figure 3 Connec...

Страница 10: ...branch box Pass the power supply cable 1 of the humidifier through the fair lead 14 and the cable fastener 15 far away from the resistor as showed in Figure 5 Insert the yellow green lead terminal of...

Страница 11: ...present will have to operate only the humidifier motor IMPORTANT when making electrical connections use insulated conductors with 1 5mm minimum cross section and 2 5mm maximum cross section Connect th...

Страница 12: ...put and remote On Off IMPORTANT when making electrical connections use insulated conductors with 1 5mm minimum cross section 3 5 1 Connections of the HDE05MP230 electrical panel to the HDU humidifier...

Страница 13: ...ty probe the terminal 2 to the terminal G supply the terminal 3 to the terminal out H output of the probe If present connect the screened shield of the probe to terminal 1 3 5 4 Alarm output Three ter...

Страница 14: ...oss section 3 6 1 Connecting the HDE10MP230 electrical panel to the first HDU humidifier Connect the terminal 60 of the electrical panel to the terminal 1 of the humidifier the terminal 70 to the term...

Страница 15: ...lled variable is displayed with decimal point precision 3 LED Reverse flashes when at least one relay ennergizes in the Reverse mode The number of flashes indicates how many relays are energized in th...

Страница 16: ...l P27 2 0 Delayed alarm P28 20 3 7 1 Setting the main parameters SET POINT St1 hold down for a few seconds St1 appears on the display release the SET 1 value flashes on the display press to change its...

Страница 17: ...rH non condensing Operating conditions 0 50 C below 90 rH non condensing Mounting DIN guide Case Plastic Index of protection IP40 panel mounting Connections Screw terminal blocks cross section 0 5mm a...

Страница 18: ...er with water 2 turn ON the humidifier 3 the atomized water will be conveyed through flexible pipes and will be spread in the environment by the air flow produced by the built in fan 4 during the humi...

Страница 19: ...and place them in fixing position Hold down the bar so that it clamps the filter against the appliance then fasten the two remaining screws 5 2 Storage Keep the appliance in a place where the temperat...

Страница 20: ...ge 7 Technical specifications Power supply 230V single phase 50Hz Rated power 0 49kW Rated current 3A External line fuse 5A AM type Air capacity 300 m3 h max Atomisation capability 1 5 5l h Water supp...

Страница 21: ......

Страница 22: ...5 VUO Via dell Industria 11 35020 Brugine Padova Italy Tel 39 049 9716611 Fax 39 049 9716600 http www carel com e mail carel carel com Agenzia JHQF Cod 030221750 rel 1 2 del 18 03 99...

Отзывы: