background image

HumiDisk - user manual

Rel. 1.2 del 18/03/99

Contents

1 GENERAL FEATURES................................................................................................................................................ 1

1.1 Applications ............................................................................................................... ................................................... 1
1.2 Operation.................................................................................................................. ..................................................... 1

2 CODES........................................................................................................................ .................................................... 2

2.1 Centrifugal Humidifier .................................................................................................................................................. 2
2.2 Electrical panels .......................................................................................................... .................................................. 2
2.3 Humidistat mounted in the HDE electric panel ............................................................................................................. 2
2.4 Accessories................................................................................................................ .................................................... 2
2.5 Humidity Probes............................................................................................................................................................ 2

3 INSTALLATION ........................................................................................................................................................... 3

3.1 Mounting................................................................................................................... .................................................... 3

3.1.1 Hanging mounting ................................................................................................................................................ 3
3.1.2 Wall mounting ...................................................................................................................................................... 3

3.2 Hydraulic connections................................................................................................................................................... 5
3.3 Setting humidifier capacity............................................................................................................................................ 5
3.4 Electrical connections ................................................................................................................................................... 6

3.4.1 Connecting the motor fan of the humidifier.......................................................................................................... 6
3.4.2 External Connections............................................................................................................................................ 7

3.5 Electrical panel HDE05MP230 for the control of one HDU centrifugal humidifier............................................................. 8

3.5.1 Connections of the  HDE05MP230 electrical panel to the  HDU humidifier ....................................................... 8
3.5.2 Connection to the electrical power ....................................................................................................................... 8
3.5.3 Connecting the humidity probe (ASH1, ASH2, ASDC11, ASDC111, ASPC11, ASPC23,ASWH1,ASWC11,
ASWC111) .................................................................................................................................................................... 9
3.5.4 Alarm output......................................................................................................................................................... 9
3.5.5 Remote ON/Off .................................................................................................................................................... 9

3.6 Control panel HDE10MP230 for the control of two HDU centrifugal humidifiers connected in parallel .................. 10

3.6.1 Connecting the  HDE10MP230 electrical panel to the first HDU humidifier .................................................... 10
3.6.2 Connecting the  HDE10MP230 electrical panel to the second HDU humidifier................................................ 10

3.7 IRDRW4000 Humidistat inside the HDE electric panel ............................................................................................. 11

3.7.1 Setting the main parameters................................................................................................................................ 12
3.7.2 IRDRW4  Technical specifications .................................................................................................................... 13

4 HUMIDIFIER START-UP.......................................................................................................... ................................ 14

4.1 Start-up................................................................................................................... ..................................................... 14
4.2 Main operations............................................................................................................ ............................................... 14
4.3 Warnings ................................................................................................................... .................................................. 14

5 MAINTENANCE .................................................................................................................. ....................................... 15

5.1 Removing and reassembling the filter ......................................................................................................................... 15
5.2 Storage .................................................................................................................... .................................................... 15
5.3 What to do before and after long periods of inactivity................................................................................................ 15
5.4 Disposal of the product .................................................................................................... ........................................... 15

6 WARRANTY CONDITIONS ..................................................................................................................................... 16

7 TECHNICAL SPECIFICATIONS ............................................................................................................................. 16

7.1 Standard references ............................................................................................................................... ..................... 16

Содержание HDU05RM230

Страница 1: ...XPL LVN 0DQXDOH G XVR 8VHU JXLGH...

Страница 2: ......

Страница 3: ...e electrical power 8 3 5 3 Connecting the humidity probe ASH1 ASH2 ASDC11 ASDC111 ASPC11 ASPC23 ASWH1 ASWC11 ASWC111 9 3 5 4 Alarm output 9 3 5 5 Remote ON Off 9 3 6 Control panel HDE10MP230 for the c...

Страница 4: ......

Страница 5: ...for wall or hanging mounting terminal block support 1 1 Applications HumiDisk is especially suitable for applications such as cold rooms and storage facilities for fresh produce where lack of humidity...

Страница 6: ...HDE electric panel Description Code IRDRW4 2 x relays Din rail mounting 24 230 Vac buzzer pre set for serial connection and remote control IRDRW4000 2 4 Accessories Description Code Remote control IR...

Страница 7: ...ceiling must be 1000mm the minimum horizontal distance from the wall must be 114mm Unit s weight is 20Kg fully loaded The machine has to be installed in horizontal position Important do not use hemp r...

Страница 8: ...Humidisk user manual Rel 1 2 del 18 03 99 4 Hanging mounting Fig 1 Wall mounting Fig 2...

Страница 9: ...air leaving the appliance must not strike any obstacle Turn the fairing D horizontally so that the flow comes out in the desired direction Fit the SAFETY fixing brackets 2 as shown in Figure 3 Connec...

Страница 10: ...branch box Pass the power supply cable 1 of the humidifier through the fair lead 14 and the cable fastener 15 far away from the resistor as showed in Figure 5 Insert the yellow green lead terminal of...

Страница 11: ...present will have to operate only the humidifier motor IMPORTANT when making electrical connections use insulated conductors with 1 5mm minimum cross section and 2 5mm maximum cross section Connect th...

Страница 12: ...put and remote On Off IMPORTANT when making electrical connections use insulated conductors with 1 5mm minimum cross section 3 5 1 Connections of the HDE05MP230 electrical panel to the HDU humidifier...

Страница 13: ...ty probe the terminal 2 to the terminal G supply the terminal 3 to the terminal out H output of the probe If present connect the screened shield of the probe to terminal 1 3 5 4 Alarm output Three ter...

Страница 14: ...oss section 3 6 1 Connecting the HDE10MP230 electrical panel to the first HDU humidifier Connect the terminal 60 of the electrical panel to the terminal 1 of the humidifier the terminal 70 to the term...

Страница 15: ...lled variable is displayed with decimal point precision 3 LED Reverse flashes when at least one relay ennergizes in the Reverse mode The number of flashes indicates how many relays are energized in th...

Страница 16: ...l P27 2 0 Delayed alarm P28 20 3 7 1 Setting the main parameters SET POINT St1 hold down for a few seconds St1 appears on the display release the SET 1 value flashes on the display press to change its...

Страница 17: ...rH non condensing Operating conditions 0 50 C below 90 rH non condensing Mounting DIN guide Case Plastic Index of protection IP40 panel mounting Connections Screw terminal blocks cross section 0 5mm a...

Страница 18: ...er with water 2 turn ON the humidifier 3 the atomized water will be conveyed through flexible pipes and will be spread in the environment by the air flow produced by the built in fan 4 during the humi...

Страница 19: ...and place them in fixing position Hold down the bar so that it clamps the filter against the appliance then fasten the two remaining screws 5 2 Storage Keep the appliance in a place where the temperat...

Страница 20: ...ge 7 Technical specifications Power supply 230V single phase 50Hz Rated power 0 49kW Rated current 3A External line fuse 5A AM type Air capacity 300 m3 h max Atomisation capability 1 5 5l h Water supp...

Страница 21: ......

Страница 22: ...5 VUO Via dell Industria 11 35020 Brugine Padova Italy Tel 39 049 9716611 Fax 39 049 9716600 http www carel com e mail carel carel com Agenzia JHQF Cod 030221750 rel 1 2 del 18 03 99...