![Cardinal RD2 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/cardinal/rd2/rd2_installation-manual_2556158013.webp)
3601-M511-O1 Rev C
•
RD2 Series
9
SETUP AND CONFIGURATION
The RD2 display has been pre-configured at the factory and should not require configuration
for use in most applications. In the event that the factory settings do not meet the
requirements of your application, the following describes the steps to configure the display.
The setup mode switch is located on the back of the
display board. You may gain access to it by
removing the 14 acorn nuts securing the rear panel
to the main housing. Refer to Figure No. 7, for the
location of the
SETUP
switch.
•
When a prompt is displayed, press the
SETUP
switch to retain the current value and proceed to
the next prompt.
•
To change a setting, press the
Up Arrow
switch to scroll through and select a new value.
•
Press the
Right Arrow
switch to "backup" to
the previous prompt.
Enter Setup Mode
1.
With the rear panel removed and the display ON, press and release the
SETUP
switch.
2.
The display will change to show
SETUP
.
3.
Press the
SETUP
switch again.
4.
The display will change to show
type=
_ and the current value.
tyPE=
(Serial Format)
This option allows you to manually select a serial format and override the Auto-format
feature by setting
type=
to a number listed below. Note that the factory default value is 0
(Auto-format is enabled).
If the value displayed is acceptable, press the
SETUP
switch again. Otherwise, press the
Up Arrow
switch to scroll through and select a new value and
then press the
SETUP
switch to save it and proceed to the next prompt. Values from 0 to 8 may be selected.
0
= Auto-format
5
= ANDFV
1
= SMA
6
= WI110
2
= Cardinal SB400
7
= Toledo Short
3
= Numbers
8
= Toledo Long
4
= Rice Lake IQ355
bAUd=
(Serial Port Baud Rate)
This option allows you to manually select a baud rate and override the Auto-baud feature by
setting
baud=
to a number listed below. Note that the factory default value is 0 (Auto-baud
is enabled).
If the value displayed is acceptable, press the
SETUP
switch again. Otherwise, press the
Up Arrow
switch to scroll through and select a new value and
then press the
SETUP
switch to save it and proceed to the next prompt. Values from 0 to 5 may be selected.
0
= Auto-baud
1
= 2400
2
= 4800
3
= 9600
4
= 19,200
5
= 38,400
Figure No. 7
Содержание RD2
Страница 2: ...3601 M511 O1 Rev C RD2 Series 2 ...
Страница 19: ...3601 M511 O1 Rev C RD2 Series 15 PART IDENTIFICATION CONT ...
Страница 20: ...3601 M511 O1 Rev C RD2 Series 16 PART IDENTIFICATION CONT ...
Страница 21: ...3601 M511 O1 Rev C RD2 Series 17 PART IDENTIFICATION CONT ...
Страница 24: ...3601 M511 O1 Rev C RD2 Series 18 ...