Page 1 

 

PRECAUTIONS 

Before using this instrument, read this 
manual and pay special attention to all 
"WARNING" symbols: 

 

 

IMPORTANT 

 ELECTRICAL 

 

 

      WARNING 

INTRODUCTION 

Thank you for your purchase of our Detecto 
VET-400 Electronic Veterinary Scale.  It was 
built with Detecto quality and reliability at our 
factory in Webb City, Missouri.  This manual 
will guide you through installation, and 
operation of your scale.  Please read it 
thoroughly before attempting to operate this 
scale and keep it handy for future reference. 

 

FCC COMPLIANCE STATEMENT  
WARNING!  

This equipment generates uses 

and can radiate radio frequency and if not 
installed and used in accordance with the 
instruction manual, may cause interference to 
radio communications.  It has been tested 
and found to comply with the limits for a Class 
A computing device pursuant to Subpart J of 
Part 15 of FCC rules, which are designed to 
provide reasonable protection against such 
interference when operated in a commercial 
environment.  Operation of this equipment in 
a residential area may cause interference in 
which case the user will be responsible to 
take whatever measures necessary to correct 
the interference. 

 

You may find the booklet "How to Identify and 
Resolve Radio TV Interference Problems" 
prepared by the Federal Communications 
Commission helpful.  It is available from the 
U.S. Government Printing Office, Washington, 
D.C. 20402.  Stock No. 001-000-00315-4. 

 

All rights reserved.  Reproduction or use, without 
expressed written permission, of editorial or pictorial 
content, in any manner, is prohibited.  No patent 
liability is assumed with respect to the use of the 
information contained herein.  While every precaution 
has been taken in the preparation of this manual, the 
Seller assumes no responsibility for errors or 
omissions.  Neither is any liability assumed for 
damages resulting from use of the information 
contained herein.  All instructions and diagrams have 
been checked for accuracy and ease of application; 
however, success and safety in working with tools 
depend to a great extent upon the individual accuracy, 
skill and caution.  For this reason the Seller is not able 
to guarantee the result of any procedure contained 
herein.  Nor can they assume responsibility for any 
damage to property or injury to persons occasioned 
from the procedures.  Persons engaging the 
procedures do so entirely at their own risk. 

TABLE OF CONTENTS 

 

INTRODUCTION ……………………………  1 

SPECIFICATIONS ………………………….  1 

UNPACKING INSTRUCTIONS ……………  2 

INSTALLATION ……………………………..  2 

Installing the Deck or Rubber Mat ……... 2 

Interconnections ………………………….  2 

Scale Base Connection …….…………… 2 

Power Supply ………………………….....  3 

Batteries …………………………………..  3 

Battery Operation ...……………………… 3 

Battery Charging …..……………………..  3 

Battery Installation/Replacement ………. 3 

OPERATION ………………………………… 5 

ERROR AND STATUS DISPLAYS ……….  6 

BEFORE YOU CALL SERVICE …………...  6 

CARE AND CLEANING …………………….  7 

PARTS IDENTIFICATION ………………….  8 

 

SPECIFICATIONS 

 

Power ……………… 
Requirements 

6 “AA” size Alkaline, 
Ni-Cad or NiMH 
batteries (not included) 
OR an optional 100 to 
240 VAC 50/60Hz 12 
VDC 1A wall plug-in 
UL/CSA listed AC 
power supply. 

 

Platform Size ………  22" x 42" x 2"   

Stainless Steel with 
Pad 

 

Capacity ……………  400 lb x .2 lb  

(180 kg x .1 kg) 

 

Operating ………….. 
Temperature 

14º to 104º F 
 (-10º to +40º C) 

 

Shipping Weight …..  73 lb 

 

 

 

 

 

Serial Number

_______________________ 

Date of Purchase 

____________________ 

Purchased Form

_____________________ 

___________________________________
___________________________________ 

 

RETAIN THIS INFORMATION FOR FUTURE USE 

Содержание Detecto VET-400

Страница 1: ...er s Manual CARDINAL SCALE MFG CO 1930 M352 O1 Rev D PO BOX 151 v WEBB CITY MO 64870 Printed in USA 11 06 PH 417 673 4631 v FAX 417 673 5001 Web Site www detectoscale com Technical Support Ph 866 254 8261 v techsupport cardet com ...

Страница 2: ......

Страница 3: ...ited No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease o...

Страница 4: ...eel deck on the scale place the scale base in front of you on a desk or table Lower the deck onto the scale base NOTE If the optional Rubber Mat was substituted for the Stainless Steel deck the mat is placed directly on the scale weighbridge Interconnections Both the VET 400 scale base and power connections to the weight indicator are made at the bottom rear panel of the indicator Refer to Figure ...

Страница 5: ...d in conjunction with the external power supply recharges the Ni Cad or NiMH batteries Because the indicator has this charging capability DO NOT connect a power supply to the indicator if using Alkaline batteries Battery Operation The weight indicator will operate for up to 250 hours on new Alkaline batteries or for up to 100 hours on fully charged Ni Cad or NiMH batteries depending on the conditi...

Страница 6: ...If replacing the batteries remove all 6 batteries from the battery holder and then proceed to step 6 6 Install the 6 new AA size batteries in the battery holder noting the polarity markings located in the battery holder Refer to Figure No 3 7 After placing all 6 batteries in the holder replace the battery cover 8 Make sure power supply is unplugged and then turn indicator over display facing up an...

Страница 7: ...unciators will turn on to show a stable center of zero weight condition Metric Conversion Press UNITS key to toggle between pounds and kilograms Note that lb or kg annunciator will turn on to show which weighing unit is active Zero Weight Display with Item on Scale 1 Place item basket box etc on scale 2 Display will show weight of item on scale 3 Press ZERO key 4 Weight display will return to zero...

Страница 8: ... POSSIBLE SOLUTIONS Display does not turn on AC Operation v Is AC power supply fully inserted into wall receptacle v Check wall receptacle for proper AC power Try another electrical appliance in same receptacle does it work v Check circuit breaker v Has there been power failure Battery operation v Check if batteries are installed and correctly v Are batteries discharged If Alkaline remove old batt...

Страница 9: ...tone or other volatile solvents for cleaning indicator or scale base v DO NOT expose equipment to temperature extremes v DO NOT place equipment in front of heating cooling vents v DO clean the indicator with a damp soft cloth and mild non abrasive detergent v DO clean the scale deck with a soft cloth dampened with a mild detergent The scale deck may be removed and washed with a mild detergent v DO...

Страница 10: ...5 4 LFB 250M LOAD CELL ASSY 6 4 0065 B108 08 ALFB FOOT 7 8 6021 2063 SHCS 3 8 24 UNF 2A x 1 9 8 6680 1043 GROMMET 10 4 6021 0106 SCW PAN HEAD 6 32x3 8 S S TYPE F PHIL DR 11 2 6021 1006 RHMS SELF TAP 10 32 UNC 2A x 1 2 12 4 6680 0068 GROMMET 13 1 3502 C331 0A J BOX ASSEMBLY 14 4 6020 0011 ROLL PIN 1 8 DIA x 3 4 LONG 16 4 6540 1122 RUBBER FOOT 0 81 DIA ...

Страница 11: ...1930 M352 O1 v VET 400 Page 9 PARTS IDENTIFICATION ...

Страница 12: ...1930 M352 O1 v VET 400 Page 10 PARTS IDENTIFICATION ...

Страница 13: ...1930 M352 O1 v VET 400 Page 11 ...

Страница 14: ... labor of the technician at the job site This limited warranty honors only labor performed by Detecto authorized dealers This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not include replacement of expendable or consumable parts This does not apply to any item which has deterior...

Страница 15: ...n with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or contract Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured The foregoing is in...

Страница 16: ...1930 M352 O1 v VET 400 Page 14 ...

Отзывы: